Are discard tubes necessary in coagulation studies?

被引:12
作者
Adcock, DM [1 ]
Kressin, DC [1 ]
Marlar, RA [1 ]
机构
[1] COLORADO PERMANENETE MED GRP,DEPT PATHOL,AURORA,CO
关键词
D O I
10.1093/labmed/28.8.530
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We evaluated the necessity of drawing a discard tube on prothrombin time (PT) and activated partial thromboplastin time (APTT) results in outpatients taking oral anticoagulant therapy. We drew two blue-stoppered tubes on 380 patients rather than the traditional practice of filling a red-top tube before filling the coagulation tube. We ran PTs and APTTs on both samples and compared results. We evaluated two sodium citrate concentrations and two prothrombin reagents, one sensitive and the other less sensitive. When PT results are reported as international normalized ratio values, no statistically significant difference exists in values between the first and second tubes filled regardless of reagent sensitivity or citrate concentration. We measured APTTs using two citrate concentrations and a factor-sensitive APTT reagent. Similarly, APTT results showed no significant difference between tubes.
引用
收藏
页码:530 / 533
页数:4
相关论文
共 13 条
  • [1] Adcock DM, 1997, AM J CLIN PATHOL, V107, P105
  • [2] BANG NU, 1971, THROMBOSIS BLEEDING, P54
  • [3] CALEM RR, 1982, CLIN CHEM, V28, P1399
  • [4] MECHANISM OF ACTION, CLINICAL EFFECTIVENESS, AND OPTIMAL THERAPEUTIC RANGE
    HIRSH, J
    DALEN, JE
    DEYKIN, D
    POLLER, L
    BUSSEY, H
    [J]. CHEST, 1995, 108 (04) : S231 - S246
  • [5] HOWANITZ JH, 1991, LAB MED TEST SELECTI, P525
  • [6] PROTHROMBIN TIME TEST - EFFECT OF VARYING CITRATE CONCENTRATION
    INGRAM, GIC
    HILLS, M
    [J]. THROMBOSIS AND HAEMOSTASIS, 1976, 36 (01) : 230 - 236
  • [7] JACOBS DS, 1994, LAB TEST HDB, P468
  • [8] JAQUES LB, 1946, CAN MED ASSOC J, V55, P26
  • [9] MCPHEDRA.P, 1974, AM J CLIN PATHOL, V62, P16
  • [10] *NAT COMM CLIN LAB, 1984, NCCLS, V4, P99