Effect of system variables involved in packed column supercritical fluid chromatography of stavudine taken as model analyte using response surface methodology along with study of thermodynamic parameters

被引:11
作者
Kaul, N. [1 ]
Agrawal, H. [1 ]
Paradkar, A. R. [1 ]
Mahadik, K. R. [1 ]
机构
[1] Bharati Vidyapeeth Deemed Univ, Poona Coll Pharm, Dept Pharmaceut Analyt Chem, Pune 411038, Maharashtra, India
关键词
column liquid chromatography; supercritical fluid chromatography; factorial design; response surface methodology; stavudine; thermodynamic parameters; Taylor-Aris peak broadening technique;
D O I
10.1016/j.jpba.2006.07.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multifactor optimization technique is successfully applied to study the effect of simultaneously varying the system variables on feasibility of stavudine analysis by packed column supercritical fluid chromatography (PC-SFC). The effect of simultaneously varying the pressure, temperature and modifier concentration was studied to optimize the method in order to obtain excellent chromatographic figures of merit. The method is based on isocratic elution using methanol-modified supercritical carbon dioxide as the mobile phase at the flow rate of 3.0 ml/min through a JASCO Finepak SIL-5, ODS [C-18 (5 mu m, 25 cm x 4.6 mm, i.d.)] column support using photodiode array detection. The optimal conditions were determined with the aid of the response surface methodology using 3 3 factorial designs. From the response surface graphs optimum regions were selected to be +1, -1. and +1 for temperature (60 degrees C), pressure (20 MPa) and percent modifier concentration (17.81%, v/v), respectively. Linearity dynamic range was found to be in the range of 2.0-150.0 mu g/ml with significantly high value of correlation coefficient. The method was validated for precision, robustness and recovery to assess the viability of the established method. The chromatographic limit of detection and quantitation were 0.80 and 1.50 mu g/ml respectively. The method has been successfully used to analyze commercial dosage form to assess the chromatographic performance of SFC system which was found to be 99.91% +/- 1.62. The present work briefs the thermodynamic applications of PC-SFC with an emphasis on the results of stavudine. The foremost of such applications is the determination of solute diffusion coefficient in supercritical mobile phase by Taylor-Aris peak broadening technique. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:471 / 480
页数:10
相关论文
共 29 条
[1]   SEPARATION OF DRUGS BY PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY .1. PHENOTHIAZINE ANTIPSYCHOTICS [J].
BERGER, TA ;
WILSON, WH .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (03) :281-286
[2]   Pharmacokinetics of intracellular zidovudine and its phosphorylated anabolites in the absence and presence of using an in vitro human peripheral blood mononuclear cell (PBMC) model [J].
Brody, SR ;
Aweeka, FT .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 1997, 9 (02) :131-135
[3]  
Carlson R., 1992, Design and Optimization in Organic Synthesis
[4]  
DAVIS OL, 1963, DESIGN ANAL IND EXPT, P789
[5]  
FARTHING D, 1992, OPTIMUM EXPT DESIGNS, P189
[6]   EFFECT OF TEMPERATURE ON PRECISION OF RETENTION MEASUREMENTS IN LIQUID-CHROMATOGRAPHY [J].
GILPIN, RK ;
SISCO, WR .
JOURNAL OF CHROMATOGRAPHY, 1980, 194 (03) :285-295
[7]  
HITCHCOCK M J M, 1991, Antiviral Chemistry and Chemotherapy, V2, P125
[8]  
*ICH, 1996, Q2B INT C HARM OCT G
[9]  
*ICH, 1994, Q2A INT C HARM OCT G
[10]  
*ICH, 2002, INT CONV QUAL PHARM