Detection of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor

被引:100
作者
Pogacnik, L [1 ]
Franko, M [1 ]
机构
[1] Nova Gorica Polytech, SL-5000 Nova Gorica, Slovenia
关键词
photothermal biosensor; cholinesterases; organophosphates and carbamates; vegetable samples;
D O I
10.1016/S0956-5663(02)00056-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Previously developed photothermal biosensor was optimised by determining the most suitable enzyme substrate (acetylthiocholine iodide) and the optimal carrier buffer (0.05 M phosphate buffer, pH 8.0). Excitation laser operating at 488 nm and 120 mW power provided the highest biosensor sensitivity. The biosensor was tested for detection of toxic organophosphate and carbamate compounds present in samples of salad, iceberg lettuce, and onion. Sufficient sensitivities to different pesticides (carbofuran, propamocarb, oxydemeton-methyl and parathion-ethyl) were achieved without time-consuming sample preparation procedures. The results show good agreement with the concentrations of pesticides determined with standard GC-MS detection method. The developed photothermal biosensor offers new low cost means to detect low concentrations of pesticides in vegetable samples with high throughput and little or no sample pretreatment. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 19 条
[1]   A BIOSENSOR AS WARNING DEVICE FOR THE DETECTION OF CYANIDE, CHLOROPHENOLS, ATRAZINE AND CARBAMATE PESTICIDES [J].
BESOMBES, JL ;
COSNIER, S ;
LABBE, P ;
REVERDY, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :255-263
[2]  
*BRIT CROP PROT CO, 1997, PEST MAN
[3]   EVALUATION OF THE USE OF FREE AND IMMOBILIZED ACETYLCHOLINESTERASE FOR PARAOXON DETECTION WITH AN AMPEROMETRIC CHOLINE OXIDASE BASED BIOSENSOR [J].
CREMISINI, C ;
DISARIO, S ;
MELA, J ;
PILLOTON, R ;
PALLESCHI, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :273-280
[4]   CHARACTERIZATION OF INHIBITORS OF ACETYLCHOLINESTERASE BY AN AUTOMATED AMPEROMETRIC FLOW-INJECTION SYSTEM [J].
GUNTHER, A ;
BILITEWSKI, U .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :117-125
[5]  
GUPTA R, 1992, PROGR PHOTOTHERMAL P, V1, P96
[6]   NEW THERMOOPTICAL MEASUREMENT METHOD AND A COMPARISON WITH OTHER METHODS [J].
HU, C ;
WHINNERY, JR .
APPLIED OPTICS, 1973, 12 (01) :72-79
[7]   TESTING, PERFORMANCE VALIDATION AND QUALITY ASSURANCE QUALITY-CONTROL OF FIELD-PORTABLE INSTRUMENTATION [J].
KOGLIN, EN ;
WILLIAMS, LR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (07) :294-299
[8]   AMPEROMETRIC FLOW-THROUGH BIOSENSOR FOR THE DETERMINATION OF PESTICIDES [J].
LAROSA, C ;
PARIENTE, F ;
HERNANDEZ, L ;
LORENZO, E .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :129-136
[9]   DETERMINATION OF ORGANOPHOSPHORUS AND CARBAMATE PESTICIDE STANDARDS BY LIQUID-CHROMATOGRAPHY WITH DETECTION BY INHIBITION OF IMMOBILIZED ACETYLCHOLINESTERASE [J].
LEONGONZALEZ, ME ;
TOWNSHEND, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 539 (01) :47-54
[10]  
*MIN HLTH REP SLOV, 1998, HDB PEST TOX PROP RE, P144