Reduction of intra- and interlaboratory variation in CD34+ stem cell enumeration using stable test material, standard protocols and targeted training

被引:78
作者
Barnett, D
Granger, V
Kraan, J
Whitby, L
Reilly, JT
Papa, S
Gratama, JW
机构
[1] Royal Hallamshire Hosp, Dept Haematol, UK NEQAS Leucocyte Immunophenotyping, Sheffield S10 2JF, S Yorkshire, England
[2] Acad Ziekenhuis, Daniel den Hoed Klin, Dept Clin & Tumour Immunol, Rotterdam, Netherlands
[3] Univ Urbino, Ist Sci Morfol, I-61029 Urbino, Italy
关键词
CD34(+) stem cell enumeration; flow cytometry; standardized protocols; clinical cell analysis;
D O I
10.1046/j.1365-2141.2000.01932.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The European Working Group on Clinical Cell Analysis (EWGCCA) has, in preparation for a multicentre peripheral blood stem cell clinical trial, developed a single-platform flow cytometric protocol for the enumeration of CD34(+) stem cells. Using this protocol, stabilized blood and targeted training, the EWGCCA have attempted to standardize CD34(+) stem cell enumeration across 24 clinical sites. Results were directly compared with participants in the UK National External Quality Assessment Scheme (NEQAS) for CD34(+) Stem Cell Quantification that analysed the same specimens using non-standardized methods. Two bead-counting systems, Flow-Count and TruCount, were also evaluated by the EWGCCA participants during trials 2 and 3. Using Flow-Count, the intralaboratory coefficient of variation (CV) was less than or equal to 5% in 39% of the laboratories (trial 1), increasing to 65% by trial 3, Interlaboratory variation was reduced from 23.3% (trial 1) to 10.8% in trial 3, In trial 2, 70% of laboratories achieved an intralaboratory CV less than or equal to 5% using TruCount, increasing to 74% for trial 3; the interlaboratory CV was reduced from 23.4% to 9.5%. Comparative analysis of the EWGCCA and the UK NEQAS cohorts revealed that EWGCCA laboratories, using the standardized approach, had lower interlaboratory variation, Thus, the use of a common standardized protocol and targeted training significantly reduced intra- and interlaboratory CD34(+) cell count variation.
引用
收藏
页码:784 / 792
页数:9
相关论文
共 36 条
  • [1] Barnett D, 1996, CYTOMETRY, V26, P216, DOI 10.1002/(SICI)1097-0320(19960915)26:3<216::AID-CYTO6>3.0.CO
  • [2] 2-C
  • [3] Barnett D, 1999, BRIT J HAEMATOL, V106, P1059
  • [4] Barnett D, 1998, BRIT J HAEMATOL, V102, P553
  • [5] BARNETT D, 1998, Patent No. 0754301
  • [6] Bender J G, 1992, J Hematother, V1, P329, DOI 10.1089/scd.1.1992.1.329
  • [7] Bergeron M, 1998, CYTOMETRY, V33, P146, DOI 10.1002/(SICI)1097-0320(19981001)33:2<146::AID-CYTO9>3.0.CO
  • [8] 2-H
  • [9] Brecher M E, 1996, J Hematother, V5, P227, DOI 10.1089/scd.1.1996.5.227
  • [10] Chang A, 1996, J Hematother, V5, P605, DOI 10.1089/scd.1.1996.5.605