Analysis of creatinine in mouse and rat serum by ion exchange high performance liquid chromatography for in vivo studies of renal function

被引:11
作者
Fountain, Kenneth J.
Kloss, Alla
Garibyan, Ilya
Blitshteyn, Bella
Brezzani, Alexander
Kyostio-Moore, Sirkka
Zuk, Anna
Sacchiero, Robert
Cohen, Aharon S.
机构
[1] Genzyme Corp, Drug & Biomat Res & Dev, Analyt Res & Dev, Waltham, MA 02451 USA
[2] Genzyme Corp, Drug & Biomat Res & Dev, Pharmacol & Preclin Dev, Waltham, MA 02451 USA
[3] Genzyme Corp, Dept Mol Biol, Framingham, MA 01701 USA
[4] Genzyme Corp, Dept Cell Biol, Framingham, MA 01701 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 846卷 / 1-2期
关键词
creatinine; renal disease; acute renal failure; cisplatin; ion exchange; high performance liquid chromatography; mouse serum; cation exchange;
D O I
10.1016/j.jchromb.2006.09.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ion exchange high performance liquid chromatography method was developed for determining creatinine levels in both mouse and rat serum samples. Separation of creatinine from other serum components was achieved in 10 min using a 100 x 4.1-mm, 10 mu m strong cation exchange column following acetonitrile precipitation of serum proteins. Incorporation of a guard cartridge placed in-line prior to the analytical column was employed to prevent interference from compounds used in renal disease animal trials. Creatinine levels in normal and diseased animals were accurately determined in the 0.01-10 mg/dL range, and average recovery of the method was approximately 85% for both mouse and rat serum. Addition of 0.5-1.0% acetic acid to the acetonitrile used for protein precipitation significantly improved creatinine recovery to above 97% in mouse serum. The method was used for routine preclinical diagnosis of rat and mouse model renal function, and for the evaluation of renal disease treatment efficacy. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 19 条
[1]  
Agrawal M, 2000, AM FAM PHYSICIAN, V61, P2077
[2]   Utility of endogenous creatinine clearance as a measure of renal function in mice [J].
Dunn, SR ;
Qi, ZH ;
Bottinger, EP ;
Breyer, MD ;
Sharma, K .
KIDNEY INTERNATIONAL, 2004, 65 (05) :1959-1967
[3]   N-acetyleysteine ameliorates lithium-induced renal failure in rats [J].
Efrati, S ;
Averbukh, M ;
Berman, S ;
Feldman, L ;
Dishy, V ;
Kachko, L ;
Weissgarten, J ;
Golik, A ;
Averbukh, Z .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 (01) :65-70
[4]   Simultaneous determination of creatinine and pseudouridine concentrations in bovine plasma by reversed-phase liquid chromatography with photodiode array detection [J].
Hewavitharana, AK ;
Bruce, HL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (02) :275-281
[5]   Kidney injury molecule-1: a tissue and urinary biomarker for nephrotoxicant-induced renal injury [J].
Ichimura, T ;
Hung, CC ;
Yang, SA ;
Stevens, JL ;
Bonventre, JV .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2004, 286 (03) :F552-F563
[6]   Simultaneous and rapid analysis of cyclosporin A and creatinine in finger prick blood samples using liquid chromatography tandem mass spectrometry and its application in C2 monitoring [J].
Keevil, BG ;
Tierney, DP ;
Cooper, DP ;
Morris, MR ;
Machaal, A ;
Yonan, N .
THERAPEUTIC DRUG MONITORING, 2002, 24 (06) :757-767
[7]   Creatinine and creatininium cation in DMSO-d6 solution.: Structure and restricted internal rotation of NH2 group [J].
Kotsyubynskyy, D ;
Molchanov, S ;
Gryff-Keller, A .
MAGNETIC RESONANCE IN CHEMISTRY, 2004, 42 (12) :1027-1036
[8]   Rapid determination of creatinine in serum and urine by ion-pair high-performance liquid chromatography [J].
Marsilio, R ;
Dall'Amico, R ;
Giordano, G ;
Murer, L ;
Montini, G ;
Ros, M ;
Bacelle, L ;
Plebani, M ;
Dussini, N ;
Zacchello, G .
INTERNATIONAL JOURNAL OF CLINICAL & LABORATORY RESEARCH, 1999, 29 (03) :103-109
[9]   PICRIC ACID METHODS GREATLY OVERESTIMATE SERUM CREATININE IN MICE - MORE ACCURATE RESULTS WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MEYER, MH ;
MEYER, RA ;
GRAY, RW ;
IRWIN, RL .
ANALYTICAL BIOCHEMISTRY, 1985, 144 (01) :285-290
[10]  
NG DSK, 1986, J CLIN CHEM CLIN BIO, V24, P565