Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology

被引:38
作者
Bunch, Dustin R. [1 ]
Miller, Abby Y. [1 ]
Wang, Sihe [1 ]
机构
[1] Cleveland Clin, Dept Clin Pathol, Clin Biochem Sect, Cleveland, OH 44195 USA
关键词
25-hydroxyvitamin D; liquid chromatography; radioimmunoassay; tandem mass spectrometry; turbulent flow; VITAMIN-D DEFICIENCY; HYPOVITAMINOSIS-D; NATIONAL-HEALTH; D INSUFFICIENCY; HUMAN PLASMA; D-2; SUPPLEMENTATION; HPLC; METABOLITES; STANDARDIZATION;
D O I
10.1515/CCLM.2009.342
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Vitamin D is important to health and disease. Liquid chromatography-tandem mass spectrometry (LC-MSMS) is considered the most accurate technology for quantification of serum 25-hydroxyvitamin D (25OHD) which is the best biomarker for estimating vitamin D nutritional status. Methods: Serum was mixed with acetonitrile containing hexadeuterated 25-hydroxyvitamin D-3 (d(6)-25OHD3) and centrifuged 10 min at 15,634xg. The supernatant was injected onto a turbulent flow preparatory column then transferred to a polar endcapped C18 analytical column. The mass spectrometer was set for positive atmospheric pressure chemical ionization. Results: The analytical cycle time was 5.5 min. Inter- and intra-assay CV for both analytes across three concentrations ranged from 3.8% to 14.2%. The method was linear from 3.0 to 283.6 nmol/L for 25-hydroxyvitamin D-3 (25OHD3) and 4.6 to 277.9 nmol/L for 25-hydroxyvitamin D-2 (25OHD2), with an accuracy of 88.7%-118.7% and 90.7%-100.3%, respectively. No carryover or ion suppression was observed. Comparison with a radioimmunoassay using patient specimens (n=527) showed a mean difference of 5.2%, and diagnostic agreement of 80.9% with Deming regression of slope 0.867, intercept 12.8, standard error of estimate (SEE) 17.4, and r=0.8425. Conclusions: The LC-MSMS method coupled with turbulent flow technology for serum 25OHD quantitation is rapid, efficient, and suitable for clinical testing. Clin Chem Lab Med 2009;47:1565-72.
引用
收藏
页码:1565 / 1572
页数:8
相关论文
共 44 条
[1]   Metabolic profiling of major vitamin D metabolites using Diels-Alder derivatization and ultra-performance liquid chromatography-tandem mass spectrometry [J].
Aronov, Pavel A. ;
Hall, Laura M. ;
Dettmer, Katja ;
Stephensen, Charles B. ;
Hammock, Bruce D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1917-1930
[2]   Assay variation confounds the diagnosis of hypovitaminosis D: A call for standardization [J].
Binkley, N ;
Krueger, D ;
Cowgill, CS ;
Plum, L ;
Lake, E ;
Hansen, KE ;
DeLuca, HF ;
Drezner, MK .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (07) :3152-3157
[3]   How accurate are assays for 25-hydroxyvitamin D? Data from the international vitamin D external quality assessment scheme [J].
Carter, GD ;
Carter, R ;
Jones, J ;
Berry, J .
CLINICAL CHEMISTRY, 2004, 50 (11) :2195-2197
[4]   Estimation of the dietary requirement for vitamin D in healthy adults [J].
Cashman, Kevin D. ;
Hill, Tom R. ;
Lucey, Alice J. ;
Taylor, Nicola ;
Seamans, Kelly M. ;
Muldowney, Siobhan ;
FitzGerald, Anthony P. ;
Flynn, Albert ;
Barnes, Maria S. ;
Horigan, Geraldine ;
Bonham, Maxine P. ;
Duffy, Emeir M. ;
Strain, J. J. ;
Wallace, Julie M. W. ;
Kiely, Mairead .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2008, 88 (06) :1535-1542
[5]   Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method [J].
Chen, Huiping ;
McCoy, Leslie F. ;
Schleicher, Rosemary L. ;
Pfeiffer, Christine M. .
CLINICA CHIMICA ACTA, 2008, 391 (1-2) :6-12
[6]   Hypovitaminosis D in the elderly: From bone to brain [J].
Cherniack, E. P. ;
Florez, H. ;
Roos, B. A. ;
Troen, B. R. ;
Levis, S. .
JOURNAL OF NUTRITION HEALTH & AGING, 2008, 12 (06) :366-373
[7]  
*CLIN LAB STAND I, 2006, PREL EV QUANT CLIN L
[8]   Summary of evidence-based review on vitamin D efficacy and safety in relation to bone health [J].
Cranney, Ann ;
Weiler, Hope A. ;
O'Donnell, Siobhan ;
Puil, Lorri .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2008, 88 (02) :513S-519S
[9]   Standardization of vitamin D assays: art or science? [J].
Fraser, William D. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 :3-4
[10]   Intake of vitamin D and risk of breast cancer - A meta-analysis [J].
Gissel, Tina ;
Rejnmark, Lars ;
Mosekilde, Leif ;
Vestergaard, Peter .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2008, 111 (3-5) :195-199