Barbed Suture for Gastrointestinal Closure: A Randomized Control Trial

被引:98
作者
Demyttenaere, Sebastian V. [1 ]
Nau, Peter [1 ]
Henn, Matthew [1 ]
Beck, Catherine [1 ]
Zaruby, Jeffrey [1 ]
Primavera, Michael [1 ]
Kirsch, David [1 ]
Miller, Jeffrey [1 ]
Liu, James J. [1 ]
Bellizzi, Andrew [1 ]
Melvin, W. Scott [1 ]
机构
[1] Ohio State Univ, Med Ctr, Dept Surg, Ctr Minimally Invas Surg, Columbus, OH 43210 USA
关键词
barbed suture; gastrointestinal anastomosis; laparoscopy; enterotomy; burst strength testing; adhesion;
D O I
10.1177/1553350609342988
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
In an effort to make laparoscopic suturing more efficient, the V-Loc advanced wound closure device (Covidien, Mansfield, MA) has been produced. This device is a self-anchoring barbed suture that obviates the need for knot tying. The goal of this initial feasibility study was to investigate the use of the barbed suture in gastrointestinal enterotomy closure. A randomized study of 12 pigs comparing enterotomy closure with barbed versus a nonbarbed suture of similar tensile strength was performed. To this end, 25 mm enterotomies were made in the stomach (1 control, 1 treatment), jejunum (2 controls, 2 treatments), and descending colon (1 control, 1 treatment). Animals were killed at 3, 7, and 14 days postoperatively (4 each group) and their gastrointestinal tracts harvested; 6 of the 8 enterotomies from each pig underwent burst strength testing. The remaining 2 were fixed in formalin and sent for histological examination. All 12 pigs survived until they were killed without any major complications. Enterotomy closure with barbed suture revealed adhesion scores, burst strength pressures, and histology scores that were similar to those for the control. Jejunal closures resulted in 6 failures at 7 days (3 control, 3 barbed) and 4 failures at 14 days (2 control, 2 barbed). The barbed suture significantly reduced suturing time in the stomach, jejunum, and colon. The V-Loc wound closure device appears to offer comparable gastrointestinal closure to 3-0 Maxon while being significantly faster. Further studies with V-Loc are required to assess its use in laparoscopic surgery.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 10 条
[1]
Objective assessment of endoscopic knot quality [J].
Hanna, GB ;
Frank, TG ;
Cuschieri, A .
AMERICAN JOURNAL OF SURGERY, 1997, 174 (04) :410-413
[2]
Ergonomic evaluation of laparoscopic bowel suturing [J].
Joice, P ;
Hanna, GB ;
Cuschieri, A .
AMERICAN JOURNAL OF SURGERY, 1998, 176 (04) :373-378
[3]
Bidirectional-barbed sutured knotless running anastomosis v classic van velthoven in a model system [J].
Moran, Michael E. ;
Marsh, Catherine ;
Perrotti, Michael .
JOURNAL OF ENDOUROLOGY, 2007, 21 (10) :1175-1177
[4]
MUELLER MD, 1995, SURG ENDOSC-ULTRAS, V9, P802
[5]
Evaluation of a novel technique for wound closure using a barbed suture [J].
Murtha, Amy P. ;
Kaplan, Andrew L. ;
Paglia, Michael J. ;
Mills, Benjie B. ;
Feldstein, Michael L. ;
Ruff, Gregory L. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 117 (06) :1769-1780
[6]
Breaking strength of barbed polypropylene sutures - Rater-blinded, controlled comparison with nonbarbed sutures of various calibers [J].
Rashid, Rashid ;
Sartori, Mark ;
White, Lucile E. ;
Villa, Mark T. ;
Yoo, Simon S. ;
Alam, Murad .
ARCHIVES OF DERMATOLOGY, 2007, 143 (07) :869-872
[7]
Ritter E Matt, 2005, Surg Innov, V12, P233, DOI 10.1177/155335060501200308
[8]
Van Sickle KR, 2005, AM SURGEON, V71, P1018
[9]
Requirements for the design and implementation of checklists for surgical processes [J].
Verdaasdonk, E. G. G. ;
Stassen, L. P. S. ;
Widhiasmara, P. P. ;
Dankelman, J. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (04) :715-726
[10]
Barbed Sutures: A Review of the Literature [J].
Villa, Mark T. ;
White, Lucile E. ;
Alam, Murad ;
Yoo, Simon S. ;
Walton, Robert L. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (03) :102E-108E