Comparison of two solid-phase microextraction methods for the quantitative analysis of VOCs in indoor air

被引:36
作者
Larroque, Virginie
Desauziers, Valerie
Mocho, Pierre
机构
[1] Ecole Mines Ales, Lab Genie Environm INd, F-64053 Pau 9, France
[2] Univ Pau & Pays Adour, Lab Therm Energet & Proc, F-64000 Pau, France
关键词
solid-phase microextraction; PDMS-carboxen; indoor air; volatile organic compounds; humidity;
D O I
10.1007/s00216-006-0714-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Competitive adsorption on adsorptive solid-phase microextraction (SPME) fibres implies careful determination of operating conditions for reliable quantitative analysis of VOCs in indoor air. With this objective, two analytical approaches, involving non-equilibrium and equilibrium extraction, were compared. The average detection limit obtained for GC-MS analysis of nine VOCs by the equilibrium method is 0.2 mu g m(-3), compared with 1.9 mu g m(-3) with the non-equilibrium method. The effect of the relative humidity of the air on the calibration plots was studied, and shown to affect acetone adsorption only. Hence, the concentrations that can be accurately determined are up to 9 mu mol m(-3). The methods were then applied to indoor air containing different concentrations of VOCs. The non-equilibrium method, involving short extraction time, can be used for detection of pollution peaks whereas equilibrium extraction is preferable for measurement of sub-mu g m(-3) ground concentration levels.
引用
收藏
页码:1457 / 1464
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 2003, 1601722003 ISO
[2]  
[Anonymous], 2004, J ZHEJIANG WANLI U
[3]   Diffusive uptake in passive and active adsorbent sampling using thermal desorption tubes [J].
Batterman, S ;
Metts, T ;
Kalliokoski, P .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (06) :870-878
[4]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[5]   Time-weighted average passive sampling with a solid-phase microextraction device [J].
Chen, Y ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2004-2010
[6]   Traceability of pollutant measurements for ambient air monitoring [J].
Desauziers, V .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (03) :252-260
[7]   Source characterization of BTEX in indoor microenvironments in Hong Kong [J].
Guo, H ;
Lee, SC ;
Li, WM ;
Cao, JJ .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (01) :73-82
[8]  
Incropera F.P., 1990, FUNDAMENTALS HEAT MA
[9]  
International Organization for Standardization, 2000, 1601712000 ISO
[10]  
ISO, 2004, 16000-1:2004. Indoor air-Part 1: general aspects of sampling strategy. International Organization for Standardization