The effect of cricoid pressure and neck support on the view at laryngoscopy

被引:63
作者
Vanner, RG
Clarke, P
Moore, WJ
Raftery, S
机构
[1] Department of Anaesthesia, Gloucestershire Royal Hospital
关键词
larynx; cricoid pressure; intubation; tracheal;
D O I
10.1111/j.1365-2044.1997.181-az0315.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Fifty female patients were studied to compare the view of the larynx at direct laryngoscopy under general anaesthesia with and without cricoid pressure applied. We also compared the view using the standard technique of cricoid pressure with that using cricoid pressure in an upward and backward direction and further investigated whether these views were improved with a firm foam rubber neck support. The order in which the types of cricoid pressure were applied nas randomised and also blinded with a drape over the neck. Cricoid pressure was simulated on weighing scales after each case and a mean force of 3.2 kg was applied. The majority of views at laryngoscopy (95%) were grade 1, with too few grade 2 and 3 views for statistical comparison. Both types of cricoid pressure applied without neck support were more likely to give a better view than no cricoid pressure (p < 0.01) and cricoid pressure in an upward and backward direction was more likely to give a better view at laryngoscopy than the standard technique (p < 0.01). Neck support during the standard technique of cricoid pressure did not improve the view of the larynx at laryngoscopy. Cricoid pressure is likely to improve the view at laryngoscopy which may be further improved by applying it in an upward and backward direction.
引用
收藏
页码:896 / 900
页数:5
相关论文
共 27 条
[1]  
[Anonymous], 1991, REP CONF ENQ MAT DEA, P73
[2]   Use of a mechanical simulator for training in applying cricoid pressure [J].
Ashurst, N ;
Rout, CC ;
Rocke, BA ;
Gouws, E .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (04) :468-472
[3]  
Benhamou D, 1995, Int J Obstet Anesth, V4, P30, DOI 10.1016/0959-289X(95)82226-Z
[4]  
Brimacombe J, 1994, Int J Obstet Anesth, V3, P211, DOI 10.1016/0959-289X(94)90071-X
[5]  
BRIMACOMBE JR, 1994, ANESTHESIA ANALGESIA, V78, P601
[6]  
Cook T M, 1994, Int J Obstet Anesth, V3, P143, DOI 10.1016/0959-289X(94)90226-7
[7]   Cricoid pressure: Are two hands better than one? [J].
Cook, TM .
ANAESTHESIA, 1996, 51 (04) :365-368
[8]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[9]  
Crawford J. S., 1984, PRINCIPLES PRACTICE
[10]   THE 'CONTRACRICOID' CUBOID AID TO TRACHEAL INTUBATION [J].
CRAWFORD, JS .
ANAESTHESIA, 1982, 37 (03) :345-345