Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water

被引:497
作者
Jambrik, Z
Monti, S
Coppola, V
Agricola, E
Mottola, G
Miniati, M
Picano, E
机构
[1] CNR, Inst Clin Physiol, I-56123 Pisa, Italy
[2] Univ Szeged, Dept Internal Med 2, H-6720 Szeged, Hungary
[3] Univ Szeged, Ctr Cardiol, H-6720 Szeged, Hungary
[4] San Raffaele Univ Hosp, Dept Cardiol, Milan, Italy
[5] Clin Cardiol Montevergine Mercogliano, Avellino, Italy
关键词
D O I
10.1016/j.amjcard.2004.02.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The "comet-tail"' is an ultrasound sign detectable with ultrasound chest instruments; this sign consists of multiple comet-tails fanning out from the lung surface. They originate from water-thickened interlobular septa and would be ideal for nonradiologic bedside assessment of extravascular lung water. To assess the feasibility and value of ultrasonic comet signs, we studied 121 consecutive hospitalized patients (43 women and 78 men; aged 67 +/- 12 years) admitted to our combined cardiology-pneumology department (including cardiac intensive care unit); the study was conducted with commercially available echocardiographic systems including a portable unit. Transducer frequencies (range 2.5 to 3.5 MHz) were used. In each patient, the right and left chest was scanned by examining predefined locations in multiple intercostal spaces. Examiners blinded to clinical diagnoses noted the presence and numbers of lung Comets at each examining site. A patient lung comet score was obtained by summing the number of comets in each of the scanning spaces. Within a few minutes, patients underwent chest x-ray, with specific assessment of extravascular lung water score by 2 pneumologist-radiologists blinded to clinical and echo findings. The chest ultrasound scan was obtained in all patients (feasibility 100%). The imaging time per examination was always <3 minutes. There was a linear correlation between echocardiographic comet score and radiologic lung water score (r = 0.78, p <0.01). Intrapatient variations (n = 15) showed an even stronger correlation between changes in echocardiographic lung comet and radiologic lung water scores (r = 0.89; p <0.01). In 121 consecutive hospitalized patients, we found a linear correlation between echocardiographic comet scores and radiologic extravascular lung water scores. Thus, the comet-tail is a simple, non-time-consuming, and reasonably accurate chest ultrasound sign of extravascular lung water that can be obtained at bedside (also with portable echocardiographic equipment) and, is not restricted by cardiac acoustic window limitations. (C) 2004 by Excerpta Medica, Inc.
引用
收藏
页码:1265 / 1270
页数:6
相关论文
共 13 条
[1]   Measurement of lung density by photon transmission for monitoring intravascular and extravascular fluid volume changes in the lungs [J].
Bergström, P ;
Jacobsson, L ;
Lomsky, M .
CLINICAL PHYSIOLOGY, 1999, 19 (06) :519-526
[2]   Does a hyperoncotic cardiopulmonary bypass prime affect extravascular lung water and cardiopulmonary function in patients undergoing coronary artery bypass surgery? [J].
Eising, GP ;
Niemeyer, M ;
Günther, T ;
Tassani, P ;
Pfauder, M ;
Schad, H ;
Lange, R .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (02) :282-289
[3]  
Giuntini C, 1988, J Thorac Imaging, V3, P36, DOI 10.1097/00005382-198807000-00010
[4]  
Givertz MM., 2001, HEART DIS, V6, P545
[5]   Early diagnosis and estimation of pulmonary congestion and edema in patients with left-sided heart diseases from histogram of pulmonary CT number [J].
Kato, S ;
Nakamoto, T ;
Iizuka, M .
CHEST, 1996, 109 (06) :1439-1445
[6]   The comet-tail artifact - An ultrasound sign of alveolar-interstitial syndrome [J].
Lichtenstein, D ;
Meziere, G ;
Biderman, P ;
Gepner, A ;
Barre, O .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (05) :1640-1646
[7]   A lung ultrasound sign allowing bedside distinction between pulmonary edema and COPD:: the comet-tail artifact [J].
Lichtenstein, D ;
Mezière, G .
INTENSIVE CARE MEDICINE, 1998, 24 (12) :1331-1334
[8]   Diuretic induced change in lung water assessed by electrical impedance tomography [J].
Noble, TJ ;
Harris, ND ;
Morice, AH ;
Milnes, P ;
Brown, BH .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) :155-163
[9]   Sustainability of medical imaging [J].
Picano, E .
BMJ-BRITISH MEDICAL JOURNAL, 2004, 328 (7439) :578-580
[10]  
PISTOLESI M, 1978, RADIOL CLIN N AM, V16, P551