Reduction of the grating lobes of annular arrays used in focused ultrasound surgery

被引:42
作者
Dupenloup, F
Chapelon, JY
Cathignol, DJ
Sapozhnikov, OA
机构
[1] Unité 281, Institut National de la Santé et de la Recherche Médicale, 69424 Lvon
关键词
D O I
10.1109/58.542044
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An annular array with variable focus, used in focused ultrasound surgery, generates grating lobes responsible for undesirable lesions, It is known that the amplitude and the location of the lobes depend on both the geometry and the frequency of the transducer. A new procedure based on the use of a wide-band CW signal, i.e., a signal phase modulated by a pseudorandom code, is proposed to reduce the amplitude of these lobes, The theoretical study enables us to determine the location and the amplitude of these lobes and to simulate the effect of the transmitted signal bandwidth, In particular, a simple analytical relation gives the intensity ratio between the grating lobes and the main lobe. This equation shows that this ratio is inversely proportional to the number of rings and to the bandwidth of the transmitted signal, A system was developed and tested with two transducer arrays of 35- and 150-mm diameter, respectively. The simulations and experiments demonstrate the validity of the theoretical study and the efficacy of the proposed procedure, In conclusion, it is possible to reduce the grating lobes without geometric modification of the array by increasing the bandwidth of the transmitted signal.
引用
收藏
页码:991 / 998
页数:8
相关论文
共 15 条
[1]   TRANSIENT FIELDS OF CONCAVE ANNULAR ARRAYS [J].
ARDITI, M ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1981, 3 (01) :37-61
[2]   HIGH-INTENSITY FOCUSED ULTRASOUND FOR THE TREATMENT OF BENIGN PROSTATIC HYPERPLASIA - EARLY UNITED-STATES CLINICAL-EXPERIENCE [J].
BIHRLE, R ;
FOSTER, RS ;
SANGHVI, NT ;
DONOHUE, JP ;
HOOD, PJ .
JOURNAL OF UROLOGY, 1994, 151 (05) :1271-1275
[3]   PHASED-ARRAY RADARS [J].
BROOKNER, E .
SCIENTIFIC AMERICAN, 1985, 252 (02) :94-&
[4]   Reduction of cavitation using pseudorandom signals [J].
Chapelon, JY ;
Dupenloup, F ;
Cohen, H ;
Lenz, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (04) :623-625
[5]  
CHAPELON JY, 1988, PROGR MED IMAGING, P227
[6]  
CHAPELON JY, P IEEE 1993 ULT S, P1211
[7]   EXPERIMENTAL EVALUATION OF A PROTOTYPE CYLINDRICAL SECTION ULTRASOUND HYPERTHERMIA PHASED-ARRAY APPLICATOR [J].
EBBINI, ES ;
CAIN, CA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (05) :510-520
[8]   PRODUCTION OF FOCAL DESTRUCTIVE LESIONS IN THE CENTRAL NERVOUS SYSTEM WITH ULTRASOUND [J].
FRY, WJ ;
MOSBERG, WH ;
BARNARD, JW ;
FRY, FJ .
JOURNAL OF NEUROSURGERY, 1954, 11 (05) :471-478
[9]  
Gelet A, 1996, EUR UROL, V29, P174
[10]   PROSTATIC TISSUE DESTRUCTION BY HIGH-INTENSITY FOCUSED ULTRASOUND - EXPERIMENTATION ON CANINE PROSTATE [J].
GELET, A ;
CHAPELON, JY ;
MARGONARI, J ;
THEILLERE, Y ;
GORRY, F ;
CATHIGNOL, D ;
BLANC, E .
JOURNAL OF ENDOUROLOGY, 1993, 7 (03) :249-253