Chemical characterisation of NIST silicate glass certified reference material SRM 610 by ICP-MS, TIMS, LIMS, SSMS, INAA, AAS and PIXE

被引:139
作者
Rocholl, ABE
Simon, K
Jochum, KP
Bruhn, F
Gehann, R
Kramar, U
Luecke, W
Molzahn, M
Pernicka, E
Seufert, M
Spettel, B
Stummeier, J
机构
[1] UNIV GOTTINGEN, INST GEOCHEM, D-37077 GOTTINGEN, GERMANY
[2] MAX PLANCK INST CHEM, D-55099 MAINZ, GERMANY
[3] RUHR UNIV BOCHUM, INST GEOL, D-4487 BOCHUM, GERMANY
[4] UNIV KARLSRUHE, INST PETROG & GEOCHEM, D-76128 KARLSRUHE, GERMANY
[5] MAX PLANCK INST KERNPHYS, D-69117 HEIDELBERG, GERMANY
来源
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS | 1997年 / 21卷 / 01期
关键词
D O I
10.1111/j.1751-908X.1997.tb00537.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
National Institute of Science and Technology (NIST) silicate glass SRM 610 is widely used as a certified reference material for various micro-analytical techniques such as SIMS or laser ablation ICP-MS. SRM 610 has been nominally doped with sixty one trace elements at the 500 mu g g(-1) level, but certified concentration data exist for only a few of these elements. This study reports concentration data for fifty nine trace elements obtained by ICP-MS, SSMS, LIMS, TIMS, INAA, AAS, and PIXE analyses of two different SRM 610 wafers. Most elements fall within a +/-10% band around a median value of about 440 mu g g(-1). The REE concentrations are shown to be constant to +/-3% (1 sigma), thus emphasizing the value of SRM 610 as a reference material for REE analyses. Comparison of our values with published data suggests that different SRM 610 wafers are, within errors, chemically identical for most elements. Exceptions to this general rule appear to be restricted to elements which were partly lost during the production of the glass, e.g. Ag and Br. On the basis of six independent determinations of Rb concentrations, which are systematically lower by a few percent than the reported NIST value, we argue that the certified Rb concentration may not be representative for all distributed SRM 610 wafers.
引用
收藏
页码:101 / 114
页数:14
相关论文
共 32 条
[1]   DETERMINATION OF LEAD, URANIUM, THORIUM, AND THALLIUM IN SILICATE GLASS STANDARD MATERIALS BY ISOTOPE DILUTION MASS-SPECTROMETRY [J].
BARNES, IL ;
GARNER, EL ;
GRAMLICH, JW ;
MOORE, LJ ;
MURPHY, TJ ;
MACHLAN, LA ;
SHIELDS, WR ;
TATSUMOT.M ;
KNIGHT, RJ .
ANALYTICAL CHEMISTRY, 1973, 45 (06) :880-885
[2]   SPARK-SOURCE MASS-SPECTROMETRIC ANALYSIS OF NBS-SRM 610 (3MM) STANDARD [J].
BERGHOLZ, J ;
LUCK, J ;
MOLLER, P ;
SZACKI, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1974, 269 (02) :121-121
[3]  
BRUHN F, 1995, THESIS RUHR U BOCHUM
[5]  
CHAMPNESS PE, 1995, MICROPROBE TECHNIQUE, P91
[6]   BORON PARTITIONING IN THE UPPER-MANTLE - AN EXPERIMENTAL AND ION PROBE STUDY [J].
CHAUSSIDON, M ;
LIBOUREL, G .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1993, 57 (23-24) :5053-5062
[7]  
GOLDSCHMIDT VM, 1937, VIDENSKAPSSELSKAP MN, V1
[8]  
Hinton R.W., 1995, MICROPROBE TECHNIQUE, V6, P235
[9]   ION MICROPROBE TRACE-ELEMENT ANALYSIS OF SILICATES - MEASUREMENT OF MULTIELEMENT GLASSES [J].
HINTON, RW .
CHEMICAL GEOLOGY, 1990, 83 (1-2) :11-25
[10]   ION PROBE MEASUREMENTS OF NATIONAL-INSTITUTE-OF-STANDARDS-AND-TECHNOLOGY STANDARD REFERENCE MATERIAL SRM-610 GLASS, TRACE-ELEMENTS [J].
HINTON, RW ;
HARTE, B ;
WITTEICKSCHEN, G .
ANALYST, 1995, 120 (05) :1315-1319