We demonstrate an apparatus for measuring time-dependent x-ray diffraction. X-ray pulses from a synchrotron are diffracted by a pair of Si(111) crystals and detected with an x-ray streak camera that has single-shot resolution of better than 1 ps. The streak camera is driven by a photoconductive su itch, which is triggered by 100-fs laser pulses at a repetition rate of 1 kHz. The laser and the streak camera are synchronized with the synchrotron pulses. In the averaging mode, trigger jitter results in 2-ps temporal resolution. We measured the duration of 5-keV pulses from the Advanced Light Source synchrotron to be 70 ps. (C) 1997 Optical Society of America.
引用
收藏
页码:1012 / 1014
页数:3
相关论文
共 9 条
  • [1] Feasibility and realization of single-pulse laue diffraction on macromolecular crystals at ESRF
    Bourgeois, D
    Ursby, T
    Wulff, M
    Pradervand, C
    Legrand, A
    Schildkamp, W
    Laboure, S
    Srajer, V
    Teng, TY
    Roth, M
    Moffat, K
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1996, 3 : 65 - 74
  • [2] Demonstration of a sub-picosecond x-ray streak camera
    Chang, Z
    Rundquist, A
    Zhou, J
    Murnane, MM
    Kapteyn, HC
    Liu, X
    Shan, B
    Liu, J
    Niu, L
    Gong, M
    Zhang, X
    [J]. APPLIED PHYSICS LETTERS, 1996, 69 (01) : 133 - 135
  • [3] CHANG Z, IN PRESS P SPIE
  • [4] KELLER R, 1996, 7 BEAM INSTR WORKSH
  • [5] KNOX W, 1980, APPL PHYS LETT, V36, P623
  • [6] Signal averaging x-ray streak camera with picosecond jitter
    Maksimchuk, A
    Kim, M
    Workman, J
    Korn, G
    Squier, J
    Du, D
    Umstadter, D
    Mourou, G
    Bouvier, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03) : 697 - 699
  • [7] Femtosecond x-ray pulses at 0.4 angstrom generated by 90 degrees Thomson scattering: A tool for probing the structural dynamics of materials
    Schoenlein, RW
    Leemans, WP
    Chin, AH
    Volfbeyn, P
    Glover, TE
    Balling, P
    Zolotorev, M
    Kim, KJ
    Chattopadhyay, S
    Shank, CV
    [J]. SCIENCE, 1996, 274 (5285) : 236 - 238
  • [8] Photolysis of the carbon monoxide complex of myoglobin: Nanosecond time-resolved crystallography
    Srajer, V
    Teng, TY
    Ursby, T
    Pradervand, C
    Ren, Z
    Adachi, S
    Schildkamp, W
    Bourgeois, D
    Wulff, M
    Moffat, K
    [J]. SCIENCE, 1996, 274 (5293) : 1726 - 1729
  • [9] LOW JITTER STREAK CAMERA TRIGGERED BY SUBPICOSECOND LASER-PULSES
    YEN, R
    DOWNEY, PM
    SHANK, CV
    AUSTON, DH
    [J]. APPLIED PHYSICS LETTERS, 1984, 44 (08) : 718 - 720