Determination of boron as boric acid in eye lotions using a sequential injection system

被引:12
作者
van Staden, JF [1 ]
Tsanwani, M [1 ]
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
关键词
sequential injection analysis; boron; eye lotions;
D O I
10.1016/S0039-9140(02)00407-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and reliable sequential injection analysis (SIA) system is described for the determination of boron as boric acid in eye lotions. This method is based on the complexation reaction between D-sorbitol and boric acid followed by the acid-base reaction with methyl orange (MO). The colour change reaction is monitored at 520 nm. The system is able to monitor boron at a frequency of 30 samples per h with a relative standard deviation of less than 0.6%. The calibration graph is linear up to 12-mg l(-1). The system has a detection limit of 0.06-mg l(-1). No significant differences (at 95% probability level) were found between the proposed SIA method and the reference method. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1103 / 1108
页数:6
相关论文
共 20 条
[1]   A SIMPLE STOPPED-FLOW METHOD WITH CONTINUOUS PUMPING FOR THE SPECTROPHOTOMETRIC FLOW-INJECTION DETERMINATION OF BORON IN PLANTS [J].
ARRUDA, MAZ ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1987, 199 :137-145
[2]   A TIME-BASED INJECTOR APPLIED TO THE FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANT MATERIALS AND SOILS [J].
CARRERO, P ;
BURGUERA, JL ;
BURGUERA, M ;
RIVAS, C .
TALANTA, 1993, 40 (12) :1967-1974
[3]   FLOW-INJECTION SPECTROFLUOROMETRIC DETERMINATION OF BORON USING ALIZARIN-RED-S IN AQUEOUS-SOLUTION [J].
CHIMPALEE, N ;
CHIMPALEE, D ;
BOONYANITCHAYAKUL, B ;
BURNS, DT .
ANALYTICA CHIMICA ACTA, 1993, 282 (03) :643-646
[4]  
CHRISTIAN GD, 1994, ANAL CHEM, P34
[5]  
DEAZEVEDOTUMANG C, 1998, ANAL CHIM ACTA, V374, P53
[6]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[7]   FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANT-MATERIAL WITH AZOMETHINE-H [J].
KRUG, FJ ;
MORTATTI, J ;
PESSENDA, LCR ;
ZAGATTO, EAG ;
BERGAMIN, H .
ANALYTICA CHIMICA ACTA, 1981, 125 (APR) :29-35
[8]   DETERMINATION OF BORON IN LIGHT-WATER AND HEAVY-WATER SAMPLES BY FLOW-INJECTION ANALYSIS WITH INDIRECT UV VISIBLE SPECTROPHOTOMETRIC DETECTION [J].
LUSSIER, T ;
GILBERT, R ;
HUBERT, J .
ANALYTICAL CHEMISTRY, 1992, 64 (19) :2201-2205
[9]  
Marshall G. D., 1992, PROCESS CONTR QUAL, V3, P251
[10]  
MCCORMACK D, 1987, MEASUREMENT STAT COM, P239