Implantable cardioverter defibrillator therapy in children with long QT syndrome

被引:42
作者
Goel, AK
Berger, S
Pelech, A
Dhala, A
机构
[1] Univ Wisconsin, Sch Med, Electrophysiol Lab, St Lukes & Aurora Sinai Med Ctr, Milwaukee, WI 53215 USA
[2] Med Coll Wisconsin, Childrens Hosp Wisconsin, Milwaukee, WI 53215 USA
关键词
long QT syndrome; implantable cardioverter defibrillator;
D O I
10.1007/s00246-003-0566-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report our experience with implantable cardioverter defibrillator (ICD) implantation and follow-up in high-risk patients with congenital long QT syndrome (LQTS). Congenital LQTS is associated with significant risk of malignant ventricular arrhythmias and sudden cardiac death (SCD). ICD implant is recommended for prevention of SCD in this patient population, but there are few published data regarding the efficacy and side effects of such therapy. We report our experience with 12 patients who underwent ICD implant for high-risk LQTS at our center in the past 5 years with respect to implant complications, appropriate and inappropriate therapies, device follow-up, and the impact on lifestyle. During a follow-up of 34.7 +/- 16.6 months, appropriate therapies were noted in 5, inappropriate therapies in 4, and no therapies in 3 patients. Clusters of appropriate therapies were seen in 3 patients, I of whom subsequently died. Female sex and congenital deafness appear to be associated with a higher risk of appropriate therapies. One patient experienced two complications at implant that were successfully treated. ICD implantation in LQTS patients presenting with SCD or recurrent syncope despite beta-blocker therapy appears to be justified in preventing SCD risk. In asymptomatic siblings of SCD patients, the benefits of ICD implant are not clear from our data.
引用
收藏
页码:370 / 378
页数:9
相关论文
共 12 条
[1]   Role of transvenous Implantable cardioverter-defibrillators in preventing sudden cardiac death in children, adolescents, and young adults [J].
Chatrath, R ;
Porter, CBJ ;
Ackerman, MJ .
MAYO CLINIC PROCEEDINGS, 2002, 77 (03) :226-231
[2]   Long-term follow-up of patients with long-QT syndrome treated with β-blockers and continuous pacing [J].
Dorostkar, PC ;
Eldar, M ;
Belhassen, B ;
Scheinman, MM .
CIRCULATION, 1999, 100 (24) :2431-2436
[3]   THE LONG QT SYNDROME IN CHILDREN - AN INTERNATIONAL STUDY OF 287 PATIENTS [J].
GARSON, A ;
DICK, M ;
FOURNIER, A ;
GILLETTE, PC ;
HAMILTON, R ;
KUGLER, JD ;
VANHARE, GF ;
VETTER, V ;
VICK, GW .
CIRCULATION, 1993, 87 (06) :1866-1872
[4]   Use of implantable cardioverter-defibrillators in the congenital long QT syndrome [J].
Groh, WJ ;
Silka, MJ ;
Oliver, RP ;
Halperin, BD ;
McAnulty, JH ;
Kron, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06) :703-706
[5]   THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN YOUNG-PATIENTS [J].
KRON, J ;
OLIVER, RP ;
NORSTED, S ;
SILKA, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :896-902
[6]   Growth and the implantable cardioverter defibrillator [J].
McLeod, KA ;
Rankin, A ;
Pollock, J .
HEART, 2000, 83 (03) :277-277
[7]   Effectiveness and limitations of β-blocker therapy in congenital long-QT syndrome [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Schwartz, PJ ;
Crampton, RS ;
Benhorin, J ;
Vincent, GM ;
Locati, EH ;
Priori, SG ;
Napolitano, C ;
Medina, A ;
Zhang, L ;
Robinson, JL ;
Timothy, K ;
Towbin, JA ;
Andrews, ML .
CIRCULATION, 2000, 101 (06) :616-623
[8]   Problems in managing patients with long QT syndrome and implantable cardioverter defibrillators: A report of two cases [J].
Perry, GY ;
Kosar, EM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (05) :863-867
[9]   Familial long QT syndrome: Electrical storm and implantable cardioverter device therapy [J].
Saxon, LA ;
Shannon, K ;
Wetzel, GT ;
Endler, LK ;
Klitzner, TS .
AMERICAN HEART JOURNAL, 1996, 131 (05) :1037-1039
[10]   LEFT CARDIAC SYMPATHETIC DENERVATION IN THE THERAPY OF CONGENITAL LONG QT SYNDROME - A WORLDWIDE REPORT [J].
SCHWARTZ, PJ ;
LOCATI, EH ;
MOSS, AJ ;
CRAMPTON, RS ;
TRAZZI, R ;
RUBERTI, U .
CIRCULATION, 1991, 84 (02) :503-511