Comparative left ventricular function following atrial, septal, and apical single chamber heart pacing in the young

被引:86
作者
Karpawich, PP [1 ]
Mital, S [1 ]
机构
[1] WAYNE STATE UNIV,CHILDRENS HOSP MICHIGAN,SCH MED,PEDIAT CARDIOL SECT,DETROIT,MI 48202
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 08期
关键词
pacing; septum; ventricular function; hemodynamics;
D O I
10.1111/j.1540-8159.1997.tb03605.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ventricular pacing, typically initiated from a RV apical electrode, inherently causes abnormal biventricular activation, decreases LV function, and causes histopathological changes. Since pacing initiated in childhood can be expected to have a more protracted course compared with the adult, the consequences of this alteration in LV hemodynamics gain added significance among the young pacemaker recipient. The purpose of this study was to evaluate the potential of improving paced LV function by a septal electrode implant site. Acute alterations in cardiac index, LV pressure, and contraction indices, including dP/dt, Vmax, and Vpm, were compared among 22 patients (median age 10 years) with normal cardiac anatomy during intracardiac electrophysiological studies. LV hemodynamics were measured during intrinsic rhythms and following 15 minutes of atrial, RV apical, and septal pacing at an appropriate exercise rate for age of 150 ppm. Results showed a significant decrease in LV dP/dt, Vmax, and Vpm, and increase in LV end-diastolic pressure only with apical pacing. Septal pacing, in spite of loss of any atrial contribution to ventricular filling, maintained comparable indices with intrinsic and atrial paced rhythms. This study demonstrates that normalized LV function is maintained by septal and deteriorates with apical pacing acutely among young, nonischemic hearts. Continued evaluation of appropriate pacing electrode designs to permit septal implant is needed to ensure optimal chronically paced LV function.
引用
收藏
页码:1983 / 1988
页数:6
相关论文
共 31 条
  • [1] MYOFIBRILLAR DISARRAY PRODUCED IN NORMAL HEARTS BY CHRONIC ELECTRICAL PACING
    ADOMIAN, GE
    BEAZELL, J
    [J]. AMERICAN HEART JOURNAL, 1986, 112 (01) : 79 - 83
  • [2] ALTERATION OF LEFT-VENTRICULAR PERFORMANCE BY LEFT-BUNDLE BRANCH-BLOCK SIMULATED WITH ATRIOVENTRICULAR SEQUENTIAL PACING
    ASKENAZI, J
    ALEXANDER, JH
    KOENIGSBERG, DI
    BELIC, N
    LESCH, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01) : 99 - 104
  • [3] BADKE FR, 1980, AM J PHYSIOL, V238, P858
  • [4] ALTERATIONS IN LEFT-VENTRICULAR RELAXATION DURING ATRIOVENTRICULAR PACING IN HUMANS
    BEDOTTO, JB
    GRAYBURN, PA
    BLACK, WH
    RAYA, TE
    MCBRIDE, W
    HSIA, HH
    EICHHORN, EJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (03) : 658 - 664
  • [5] MECHANICAL PERFORMANCE AND EFFICIENCY OF LEFT VENTRICLE DURING VENTRICULAR STIMULATION
    BOERTH, RC
    COVELL, JW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1971, 221 (06): : 1686 - &
  • [6] INFLUENCE OF PACING SITE ON CANINE LEFT-VENTRICULAR CONTRACTION
    BURKHOFF, D
    OIKAWA, RY
    SAGAWA, K
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (02): : H428 - H435
  • [7] INFLUENCE OF PACING SITE ON CANINE LEFT-VENTRICULAR FORCE-INTERVAL RELATIONSHIP
    BURKHOFF, D
    SAGAWA, K
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (03): : H414 - H418
  • [8] FUNCTIONAL ABNORMALITIES IN ISOLATED LEFT-BUNDLE BRANCH-BLOCK - THE EFFECT OF INTERVENTRICULAR ASYNCHRONY
    GRINES, CL
    BASHORE, TM
    BOUDOULAS, H
    OLSON, S
    SHAFER, P
    WOOLEY, CF
    [J]. CIRCULATION, 1989, 79 (04) : 845 - 853
  • [9] ALTERATIONS IN PRELOAD AND MYOCARDIAL MECHANICS IN DOG AND IN MAN
    GROSSMAN, W
    SALTZ, S
    HAYNES, F
    DEXTER, L
    PARASKOS, JA
    DALEN, JE
    [J]. CIRCULATION RESEARCH, 1972, 31 (01) : 83 - +
  • [10] ENDOCARDIAL PACING SITE AFFECTS LEFT-VENTRICULAR END-DIASTOLIC VOLUME AND PERFORMANCE IN THE INTACT ANESTHETIZED DOG
    GROVER, M
    GLANTZ, SA
    [J]. CIRCULATION RESEARCH, 1983, 53 (01) : 72 - 85