On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system

被引:133
作者
Kurita, Ryoji [1 ]
Yokota, Yoshimi [1 ]
Sato, Yukari [1 ]
Mizutani, Fumio [1 ]
Niwa, Osamu [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki, Japan
关键词
D O I
10.1021/ac060480y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports a miniaturized immunosensor designed to determine a trace level cardiac marker, B-type natriuretic peptide (BNP), using a microfluidic device combined with a portable surface plasmon resonance (SPR) sensor system. Sample BNP solution was introduced into the microchannel after an immunoreaction with acetylcholine esterase-labeled antibody (conjugate), and only unbound conjugate was trapped on the BNP-immobilized surface in the flow channel. Then, the thiol compound generated by the enzymatic reaction with the trapped conjugate was accumulated on a gold thin film located downstream in the microchannel to monitor the real-time SPR angle shift. We achieved a detectable concentration range of 5 pg/mL-100 ng/mL by monitoring the SPR angle shift, which covers the required detection range for the BNP concentrations found in blood. This success resulted from the use of a T-shaped microfluidic device structure, which prevents the sample solution from flowing over the gold film used for SPR detection. We were able to measure trace levels of BNP peptide (15 fg) within 30 min since the procedure with our immunosensor is simpler than a multistep immunoassay through the simultaneous use of a labeled enzymatic reaction and the real-time monitoring of enzymatic product accumulation in the microfluidic device. We employed the procedure to detect serum BNP by using spiked samples in human serum and achieved satisfactory recovery for heat-treated samples to denature the esterase in the serum before the immunoreaction.
引用
收藏
页码:5525 / 5531
页数:7
相关论文
共 47 条
  • [1] A surface plasmon resonance probe with a novel integrated reference sensor surface
    Akimoto, T
    Ikebukuro, K
    Karube, I
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (12) : 1447 - 1453
  • [2] Resistance to nonspecific protein adsorption by poly(vinyl alcohol) thin films adsorbed to a poly(styrene) support matrix studied using surface plasmon resonance
    Barrett, DA
    Hartshorne, MS
    Hussain, MA
    Shaw, PN
    Davies, MC
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5232 - 5239
  • [3] High-sensitivity miniaturized immunoassays for tumor necrosis factor a using microfluidic systems
    Cesaro-Tadic, S
    Dernick, G
    Juncker, D
    Buurman, G
    Kropshofer, H
    Michel, B
    Fattinger, C
    Delamarche, E
    [J]. LAB ON A CHIP, 2004, 4 (06) : 563 - 569
  • [4] Maximizing the natriuretic peptide system in experimental heart failure - Subcutaneous brain natriuretic peptide and acute vasopeptidase inhibition
    Chen, HH
    Lainchbury, JG
    Harty, GJ
    Burnett, JC
    [J]. CIRCULATION, 2002, 105 (08) : 999 - 1003
  • [5] Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay
    Cheng, SB
    Skinner, CD
    Taylor, J
    Attiya, S
    Lee, WE
    Picelli, G
    Harrison, DJ
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1472 - 1479
  • [6] COADSORPTION OF FERROCENE-TERMINATED AND UNSUBSTITUTED ALKANETHIOLS ON GOLD - ELECTROACTIVE SELF-ASSEMBLED MONOLAYERS
    CHIDSEY, CED
    BERTOZZI, CR
    PUTVINSKI, TM
    MUJSCE, AM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (11) : 4301 - 4306
  • [7] Cell immobilization using self-assembled synthetic oligopeptide and its application to biological toxicity detection using surface plasmon resonance
    Choi, JW
    Park, KW
    Lee, DB
    Lee, W
    Lee, WH
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) : 2300 - 2305
  • [8] Utility of B-type natriuretic peptide in the diagnosis of congestive heart failure in an urgent-care setting
    Dao, Q
    Krishnaswamy, P
    Kazanegra, R
    Harrison, A
    Amirnovin, R
    Lenert, L
    Clopton, P
    Alberto, J
    Hlavin, P
    Maisel, AS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 379 - 385
  • [9] Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    Duffy, DC
    McDonald, JC
    Schueller, OJA
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4974 - 4984
  • [10] A NEW AND RAPID COLORIMETRIC DETERMINATION OF ACETYLCHOLINESTERASE ACTIVITY
    ELLMAN, GL
    COURTNEY, KD
    ANDRES, V
    FEATHERSTONE, RM
    [J]. BIOCHEMICAL PHARMACOLOGY, 1961, 7 (02) : 88 - &