Foreign-body reaction to the bioabsorbable Suretac device

被引:77
作者
Burkart, A [1 ]
Imhoff, AB [1 ]
Roscher, E [1 ]
机构
[1] Tech Univ Munich, Dept Orthoped Sports Med, D-80809 Munich, Germany
关键词
foreign; body reaction; Suretac; shoulder stabilization; shoulder instability;
D O I
10.1016/S0749-8063(00)90134-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Arthroscopic shoulder stabilization with the bioabsorbable Suretac device (Acufex Microsurgical, Mansfield, MA) offers some technical advantages compared with other approaches. However,: in 4 patients (3 men, 1 woman; between 20 and 35 years of age) with 3 SLAP lesions grades 2 and 1 post-traumatic anterior shoulder instability, breakage and early loosening of the Suretac device was observed. All patients complained about shoulder pain and loss of active and passive motion. The arthroscopic examination revealed a massive synovitis without positive cultures. Loose fragments of the Suretac device spread in the joint cavity and induced a foreign-body reaction. Histologically, there was a massive infiltration of phagocytic cells (histiocytes, multinucleated giant cells) and birefringent polymeric particles surrounded by:or within histiocytes and multinucleated giant cells. All patients underwent arthroscopic synovectomy. Because of instability, 2 of them required restabilization. which was performed with suture anchors (Fastak [Arthrex, Naples, FL], Mitek [Mitek Division, Ethicon, Norder-stedt, Germany]). Postoperatively all patients were:pain; free, progressing to full active and passive range of motion. Our patients suffered from a mechanical failure rather than from a predisposition to exaggerated inflammatory response. According to this observation, the Suretac device seems to be prone to early failure in patients with SLAP lesions because of its biodegradability.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 24 条
[1]   FOREIGN-BODY REACTIONS TO POLYGLYCOLIDE SCREWS - OBSERVATIONS IN 24/216 MALLEOLAR FRACTURE CASES [J].
BOSTMAN, O ;
PARTIO, E ;
HIRVENSALO, E ;
ROKKANEN, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (02) :173-176
[2]   INTENSE GRANULOMATOUS INFLAMMATORY LESIONS ASSOCIATED WITH ABSORBABLE INTERNAL-FIXATION DEVICES MADE OF POLYGLYCOLIDE IN ANKLE FRACTURES [J].
BOSTMAN, OM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (278) :193-199
[3]  
DUTOIT GT, 1956, J BONE JOINT SURG AM, V38, P1
[4]  
Edwards D J, 1994, J Shoulder Elbow Surg, V3, P230, DOI 10.1016/S1058-2746(09)80040-2
[5]  
FELLMANN J, 1995, SPORTORTHOP SPORTTRA, V11, P255
[6]  
HAWKINS R B, 1989, Arthroscopy, V5, P122
[7]  
IMHOFF AB, 1996, 2 CENTR EUR C TRAUM
[8]  
JOHNSON LL, 1993, DIAGNOSTIC SURG ARTH, P276
[9]   ARTHROSCOPIC STAPLE CAPSULORRHAPHY - A LONG-TERM FOLLOW-UP [J].
LANE, JG ;
SACHS, RA ;
RIEHL, B .
ARTHROSCOPY, 1993, 9 (02) :190-194
[10]   INITIAL FAILURE STRENGTH OF OPEN AND ARTHROSCOPIC BANKART REPAIRS [J].
MCELENEY, ET ;
DONOVAN, MJ ;
SHEA, KP ;
NOWAK, MD .
ARTHROSCOPY, 1995, 11 (04) :426-431