Intercomparison experiments of systems for the measurement of xenon radionuclides in the atmosphere

被引:90
作者
Auer, M
Axelsson, A
Blanchard, X
Bowyer, TW
Brachet, G
Bulowski, I
Dubasov, Y
Elmgren, K
Fontaine, JP
Harms, W
Hayes, JC
Heimbigner, TR
McIntyre, JI
Panisko, ME
Popov, Y
Ringbom, A
Sartorius, H
Schmid, S
Schulze, J
Schlosser, C
Taffary, T
Weisse, W
Wernsperger, B
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
[2] Comprehens Nucl Test Ban Treaty Org, Preparatory Commiss, A-1400 Vienna, Austria
[3] Swedish Def Res Agcy, Stockholm, Sweden
[4] Commissariat Energie Atom, F-91680 Bruyeres Le Chatel, France
[5] Fed Off Radiat Protect, D-79098 Freiburg, Germany
[6] VG Khlopin Radium Inst, St Petersburg 197022, Russia
关键词
CTBT; environmental monitoring; international monitoring system; noble gas; radioactivity monitoring; radioxenon; xenon;
D O I
10.1016/j.apradiso.2004.01.011
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Radioactive xenon monitoring is one of the main technologies used for the detection of underground nuclear explosions. Precise and reliable measurements of Xe-131m, Xe-133g, Xe-133m, and Xe-135g are required as part of the International Monitoring System for compliance with the Comprehensive Nuclear-Test-Ban Treat (CTBT). For the first time, simultaneous testing of four highly sensitive and automated fieldable radioxenon measurement systems has been performed and compared to established laboratory techniques. In addition to an intercomparison of radioxenon monitoring equipment of different design, this paper also presents a set of more than 2000 measurements of activity concentrations of radioactive xenon made in the city of Freiburg, Germany in 2000. The intercomparison experiment showed, that the results from the newly developed systems agree with each other and the equipment fulfills the fundamental requirements for their use in the verification regime of the CTBT. For 24-h measurements, concentrations as low as 0.1 mBq m(-3) were measured for atmospheric samples ranging in size from 10 to 80 m(3). The Xe-133 activity concentrations detected in the ambient air ranged from below 1 mBq m(-3) to above 100 mBq m(-3). (C) 2004 Published by Elsevier Ltd.
引用
收藏
页码:863 / 877
页数:15
相关论文
共 29 条
[1]  
[Anonymous], 1987, CRC HDB CHEM PHYS
[2]  
Bernstrom B., 1983, C20515A1 FOA
[3]   Detection and analysis of xenon isotopes for the comprehensive nuclear-test-ban treaty international monitoring system [J].
Bowyer, TW ;
Schlosser, C ;
Abel, KH ;
Auer, M ;
Hayes, JC ;
Heimbigner, TR ;
McIntyre, JI ;
Panisko, ME ;
Reeder, PL ;
Satorius, H ;
Schulze, J ;
Weiss, W .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2002, 59 (02) :139-151
[4]   Ambient Xe-133 levels in the northeast US [J].
Bowyer, TW ;
Abel, KH ;
Hensley, WK ;
Panisko, ME ;
Perkins, RW .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1997, 37 (02) :143-153
[5]  
BOWYER TW, 1998, ENCY ENV ANAL REMEDI, P5299
[6]  
BOWYER TW, 1996, PNL11424 PAC NW NAT
[7]  
BROWNE E, 1986, TABLE RADIOACTIVE IT
[8]  
CARRIGAN CR, 1996, NATURE, V202, P528
[9]   A conditional density approach to the order determination of time series [J].
Finkenstädt, BF ;
Yao, QW ;
Tong, H .
STATISTICS AND COMPUTING, 2001, 11 (03) :229-240
[10]  
FONTAINE JP, 2002, P INT C IN SIT NUCL