Mechanistic significance of intermittent pulmonary vein tachycardia in patients with atrial fibrillation

被引:153
作者
Oral, H [1 ]
Özaydin, M [1 ]
Tada, H [1 ]
Chugh, A [1 ]
Scharf, C [1 ]
Hassan, S [1 ]
Lai, S [1 ]
Greenstein, R [1 ]
Pelosi, F [1 ]
Knight, BP [1 ]
Strickberger, SA [1 ]
Morady, F [1 ]
机构
[1] Univ Michigan, Dept Internal Med, Div Cardiol, Ann Arbor, MI 48109 USA
关键词
atrial fibrillation; radiofrequency catheter ablation; pulmonary vein;
D O I
10.1046/j.1540-8167.2002.00645.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The significance of intermittent tachycardia within a pulmonary vein (PV) during an episode of atrial fibrillation (AF) is unclear. The aim of this study was to determine the role that intermittent PV tachycardias play in AF. Methods and Results: In 56 patients with AF, segmental ostial ablation guided by PV potentials was performed to isolate the PVs. The characteristics of intermittent PV tachycardias and the inducibility of AF before and after PV isolation were analyzed prospectively. During AF, a PV tachycardia (mean cycle length 130 +/- 30 msec) with exit block to the left atrium was present in 93% of left superior, 80% of left inferior, 73% of right superior, and 7% of right inferior PVs. The site of shortest cycle length during AF alternated between the PVs and left atrium I to 13 times per minute. Complete isolation was achieved in 168 (94%) of 178 targeted PVs. In 99% of PVs, tachycardia resolved upon isolation. AF was persistent before and after PV isolation in 100% and 27% of patients, respectively (P < 0.001). Conclusion: Intermittent bursts of tachycardia are observed within multiple PVs during persistent AF in a majority of patients. After PV isolation, PV tachycardias almost always resolve, and AF is less likely to be inducible or persistent. These observations suggest a dynamic interplay between the atria and PVs, with intermittent bursts of PV tachycardia being dependent on left atrial input and with the probability of persistent AF diminishing when PV tachycardias are eliminated by PV isolation.
引用
收藏
页码:645 / 650
页数:6
相关论文
共 7 条
[1]  
Allessie MA, 2001, CIRCULATION, V103, P769
[2]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[3]   PULMONARY VEIN AS AN ECTOPIC FOCUS IN DIGITALIS-INDUCED ARRHYTHMIA [J].
CHEUNG, DW .
NATURE, 1981, 294 (5841) :582-584
[4]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[5]   Surgery for atrial fibrillation using radiofrequency catheter ablation: assessment of results at one year [J].
Melo, J ;
Adragao, P ;
Neves, J ;
Ferreira, MM ;
Pinto, MM ;
Rebocho, MJ ;
Parreira, L ;
Ramos, T .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (06) :851-854
[6]   Prevalence and significance of exit block during arrhythmias arising in pulmonary veins [J].
Tse, HF ;
Lau, CP ;
Kou, W ;
Pelosi, F ;
Oral, H ;
Kim, M ;
Michaud, GF ;
Knight, BP ;
Moscucci, M ;
Strickberger, SA ;
Morady, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (04) :379-386
[7]   ATRIAL-FIBRILLATION BEGETS ATRIAL-FIBRILLATION - A STUDY IN AWAKE CHRONICALLY INSTRUMENTED GOATS [J].
WIJFFELS, MCEF ;
KIRCHHOF, CJHJ ;
DORLAND, R ;
ALLESSIE, MA .
CIRCULATION, 1995, 92 (07) :1954-1968