The influence of manufacturing procedure on the degradation of poly(lactide-co-glycolide) 85:15 and 50:50 implants

被引:56
作者
Ramchandani, M
Pankaskie, M
Robinson, D
机构
[1] UNIV PITTSBURGH,MED CTR,DRUG INFORMAT & EPIDEMIOL CTR,PITTSBURGH,PA 15261
[2] UNIV NEBRASKA,MED CTR,COLL PHARM,DEPT PHARMACEUT SCI,OMAHA,NE 68105
关键词
poly(lactides-co-glycolides); microcapsules; nonsolvent phase separation; polymer degradation; surface morphology; degradation time;
D O I
10.1016/S0168-3659(96)01481-2
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Poly(lactides-co-glycolides) (PLGA) are widely investigated biodegradable polymers and are extensively used in several biomaterials applications as well as drug delivery systems. The PLGA polymers degrade by bulk hydrolysis of ester bonds and breakdown into their constituent monomers, lactic and glycolic acids which are excreted from the body. The purpose of this investigation was to study the effect of manufacturing procedure on the in vitro degradation of two PLGA copolymers, 85:15 and 50:50, which were fabricated as implants, Implants were compressed from microcapsules prepared by nonsolvent induced phase separation using two solvent-nonsolvent systems, viz., methylene chloride-hexane (non-polar) and acetone-phosphate buffer (polar). Studies were performed at pH 4.5, 7.4 and 9.4 and polymer degradation was monitored by measuring the decrease in number- and weight-average molecular weights (M(n) and M(w)), mass loss, formation of lactic and glycolic acids and pH of the degradation medium. Representative scanning electron micrographs (SEMs) were also obtained to study the changes in surface morphology of the implants. Results of these studies indicated that both PLGA 85:15 and 50:50 implants prepared by the non-polar procedure degraded faster than the implants prepared by the polar procedure. The decrease in polymer M(n) and M(w) followed pseudo first-order kinetics. Changes in M(n) and M(w) occurred before the onset of mass loss, after which implant mass loss was described by pseudo first order kinetics. The appearance of lactic and glycolic acids corresponded to the initiation of mass loss and also resulted in decrease in pH of the bulk degradation medium. The SEMs indicated that water uptake was faster in implants prepared by the non-polar method resulting in a more porous matrix which degrades more rapidly. Finally, the average degradation time for PLGA 85:15 was approximate to 26 weeks and that for PLGA 50:50 was 6-8 weeks.
引用
收藏
页码:161 / 173
页数:13
相关论文
共 19 条
[1]  
[Anonymous], 1992, ADV PHARM S
[2]   THE ACCELERATION OF DEGRADATION-CONTROLLED DRUG DELIVERY FROM POLYESTER MICROSPHERES [J].
CHA, Y ;
PITT, CG .
JOURNAL OF CONTROLLED RELEASE, 1989, 8 (03) :259-265
[3]   A COMPARISON OF THE EFFECT OF PH ON THE BIODEGRADATION OF 2 SYNTHETIC ABSORBABLE SUTURES [J].
CHU, CC .
ANNALS OF SURGERY, 1982, 195 (01) :55-59
[4]   INVIVO CHARACTERISTICS OF HIGH-MOLECULAR-WEIGHT COPOLY(L-LACTIDE GLYCOLIDE) WITH S-TYPE DEGRADATION PATTERN FOR APPLICATION IN DRUG DELIVERY SYSTEMS [J].
FUKUZAKI, H ;
YOSHIDA, M ;
ASANO, M ;
KUMAKURA, M ;
MASHIMO, T ;
YUASA, H ;
IMAI, K ;
YAMANAKA, H .
BIOMATERIALS, 1991, 12 (04) :433-437
[5]  
GILDING DK, 1981, FUNDAMENTAL ASPECTS, V1, P43
[6]  
HUTCHINSON F, 1987, J CONTROL RELEASE, V13, P279
[7]   POLY(LACTIDE-CO-GLYCOLIDE) DECOMPOSITION KINETICS INVIVO AND INVITRO [J].
KENLEY, RA ;
LEE, MO ;
MAHONEY, TR ;
SANDERS, LM .
MACROMOLECULES, 1987, 20 (10) :2398-2403
[8]  
Lewis D.H., 1990, Biodegradable polymers as drug delivery systems, P1
[9]   STRUCTURE PROPERTY RELATIONSHIPS IN THE CASE OF THE DEGRADATION OF MASSIVE POLY(ALPHA-HYDROXY ACIDS) IN AQUEOUS-MEDIA .2. DEGRADATION OF LACTIDE-GLYCOLIDE COPOLYMERS - PLA37.5GA25 AND PLA75GA25 [J].
LI, SM ;
GARREAU, H ;
VERT, M .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1990, 1 (03) :131-139
[10]   STRUCTURE PROPERTY RELATIONSHIPS IN THE CASE OF THE DEGRADATION OF MASSIVE ALIPHATIC POLY-(ALPHA-HYDROXY ACIDS) IN AQUEOUS-MEDIA .1. POLY(DL-LACTIC ACID) [J].
LI, SM ;
GARREAU, H ;
VERT, M .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1990, 1 (03) :123-130