Acute and chronic reduction of functional mitral regurgitation in experimental heart failure by percutaneous mitral annuloplasty

被引:104
作者
Maniu, CV
Patel, JB
Reuter, DG
Meyer, DM
Edwards, WD
Rihal, CS
Redfield, MM
机构
[1] Mayo Clin & Mayo Fdn, Cardiorenal Lab, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Div Pathol, Rochester, MN 55905 USA
[3] Cardiac Dimens Inc, Kirkland, WA USA
关键词
D O I
10.1016/j.jacc.2004.03.085
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to determine acute and chronic efficacy of a percutaneous mitral annuloplasty (PMA) device in experimental heart failure (HF). Further, we evaluated the potential for adverse effects on left ventricular (LV) function and coronary perfusion. BACKGROUND Reduction of mitral annular dimension with a PMA device in the coronary sinus may reduce functional mitral regurgitation (MR) in advanced HF. METHODS Study 1: a PMA device was placed acutely in anesthetized open-chest dogs with rapid pacing-induced HF (n = 6) instrumented for pressure volume analysis. Study 2: in 12 anesthetized dogs with HF, fluoroscopic-guided PMA was performed, and dogs were followed for four weeks with continuing rapid pacing. RESULTS Study 1: percutaneous mitral annuloplasty reduced annular dimension and severity of MR at baseline and with phenylephrine infusion to increase afterload (MR jet/left atrial [LA] area 26 +/- 1% to 7 +/- 2%, p < 0.05). Pressure volume analysis demonstrated no acute impairment of LV function. Study 2: no device was placed in two dogs because of prototype size limitations. Attempted PMA impaired coronary flow in three dogs. Percutaneous mitral annuloplasty (n = 7) acutely reduced MR (MR jet/LA area 43 +/- 4% to 8 +/- 5%, p < 0.0001), regurgitant volume (14.7 +/- 2.1 ml to 3.1 +/- 0.5 ml, p < 0.05), effective regurgitant orifice area +/- 0.010 cm(2) to cm(2), (0.130 +/- 0.040 +/- 0.003 p < 0.05), and angiographic MR grade (2.8 +/- 0.3 device to 1.0 +/- 0.3 device, p < 0.001). In the conscious state, MR was reduced at four weeks after PMA (MR jet/LA area 33 +/- 3% HF baseline vs. 11 +/- 4% four weeks after device, P < 0.05). CONCLUSIONS Percutaneous mitral annuloplasty results in acute and chronic reduction of functional MR in experimental HF. (C) 2004 by the American College of Cardiology Foundation.
引用
收藏
页码:1652 / 1661
页数:10
相关论文
共 17 条
[1]   Intermediate-term outcome of mitral reconstruction in cardiomyopathy [J].
Bolling, SF ;
Pagani, FD ;
Deeb, GM ;
Bach, DS .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (02) :381-386
[2]  
Chen Frederick Y, 2002, Cardiol Rev, V10, P326, DOI 10.1097/00045415-200211000-00004
[3]   COLOR DOPPLER ASSESSMENT OF MITRAL REGURGITATION WITH ORTHOGONAL PLANES [J].
HELMCKE, F ;
NANDA, NC ;
HSIUNG, MC ;
SOTO, B ;
ADEY, CK ;
GOYAL, RG ;
GATEWOOD, RP .
CIRCULATION, 1987, 75 (01) :175-183
[4]   Feasibility and short-term efficacy of percutaneous mitral annular reduction for the therapy of heart failure-induced mitral regurgitation [J].
Kaye, DM ;
Byrne, M ;
Alferness, C ;
Power, J .
CIRCULATION, 2003, 108 (15) :1795-1797
[5]   Prognostic significance of mitral regurgitation and tricuspid regurgitation in patients with left ventricular systolic dysfunction [J].
Koelling, TM ;
Aaronson, KD ;
Cody, RJ ;
Bach, DS ;
Armstrong, WF .
AMERICAN HEART JOURNAL, 2002, 144 (03) :524-529
[6]   Mitral ring annuloplasty: An incomplete correction of functional mitral regurgitation associated with left ventricular remodeling [J].
Lachmann J. ;
Shirani J. ;
Plestis K.A. ;
Frater R.W.M. ;
LeJemtel T.H. .
Current Cardiology Reports, 2001, 3 (3) :241-246
[7]  
Lamas GA, 1997, CIRCULATION, V96, P827
[8]   LARGE ANIMAL-MODEL OF ISCHEMIC MITRAL REGURGITATION [J].
LLANERAS, MR ;
NANCE, ML ;
STREICHER, JT ;
LIMA, JAC ;
SAVINO, JS ;
BOGEN, DK ;
DEAC, RFP ;
RATCLIFFE, MB ;
EDMUNDS, LH .
ANNALS OF THORACIC SURGERY, 1994, 57 (02) :432-439
[9]   Hemodynamic and humoral effects of vasopeptidase inhibition in canine hypertension [J].
Maniu, CV ;
Meyer, DM ;
Redfield, MM .
HYPERTENSION, 2002, 40 (04) :528-534
[10]  
Oh JK, 1999, ECHO MANUAL, P103