Comparison of random and oriented immobilisation of antibody fragments on mixed self-assembled monolayers

被引:125
作者
Bonroy, Kristien
Frederix, Filip
Reekmans, Gunter
Dewolf, Ellen
De Palma, Randy
Borghs, Gustaaf
Declerck, Paul
Goddeeris, Bruno
机构
[1] Katholieke Univ Leuven, Lab Pharmaceut Biol & Phytopharmacol, B-3000 Louvain, Belgium
[2] IMEC, MCP, ART, B-3001 Louvain, Belgium
[3] Katholieke Univ Leuven, Lab Physiol & Immunol Domest Anim, B-3001 Louvain, Belgium
[4] Univ Ghent, Immunol Lab, B-9820 Merelbeke, Belgium
关键词
antibody fragments; mixed self-assembled monolayers; SPR biosensor; oriented coupling;
D O I
10.1016/j.jim.2006.03.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The sensitivity of immunosensors is strongly dependent on the amount of immobilised antibodies and their remaining antigen binding properties. The use of smaller and well-oriented antibody fragments as bioreceptor molecules influences the final immunosensor signal. The aim of this study was to compare the immumosensor responses of different immobilised antibody fragments, such as F(ab')(2) and Fab', with their parental IgG. In addition, we evaluated the oriented versus the random covalent immobilisation method of the Fab' fragments. First, an optimisation of cleavage protocol to generate these F(ab')(2) and Fab' fragments was performed. Subsequently, we pursued a study with limited denaturation effects during immobilisation of the bioreceptor molecules and with reduced steric hindrance during antigen binding using mixed self-assembled monolayers (SAM) of thiols as the chemical linking layer. The Surface Plasmon Resonance technique was used to evaluate the degree of immobilisation of the antibody fragments and their parental IgGs on the mixed SAMs and the binding signals of their specific antigens. In this study, we demonstrate that for a particular antibody/antigen system (anti-hIgG/hIgG), the optimised fragmentation protocol in combination with an oriented immobilisation of Fab' fragments on mixed SAMs leads to a > 2-fold increase of the antigen binding signals compared to randomly covalent immobilised full-length antibodies. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:167 / 181
页数:15
相关论文
共 70 条
[1]   IMPROVEMENT OF ANTIBODY SURFACE-DENSITY BY ORIENTATION OF REDUCED FRAGMENTS [J].
AHLUWALIA, A ;
CARRA, M ;
DEROSSI, D ;
RISTORI, C ;
TUNDO, P ;
BOMBEN, A .
THIN SOLID FILMS, 1994, 247 (02) :244-247
[2]   ANTIGEN RECOGNITION PROPERTIES OF ANTIBODY MONOLAYERS [J].
AHLUWALIA, A ;
DEROSSI, D ;
SCHIRONE, A .
THIN SOLID FILMS, 1992, 210 (1-2) :726-729
[3]  
ASLAM M, 1999, BIOCONJUGATION
[4]  
Boyer Rodney, 1993, Modern Experimental Biochemistry, VSecond
[5]   Direct oriented immobilization of F(ab′) antibody fragments on gold [J].
Brogan, KL ;
Wolfe, KN ;
Jones, PA ;
Schoenfisch, MH .
ANALYTICA CHIMICA ACTA, 2003, 496 (1-2) :73-80
[6]   ADSORPTION OF MONOCLONAL IGGS AND THEIR F(AB')(2) FRAGMENTS ONTO POLYMERIC SURFACES [J].
BUIJS, J ;
LICHTENBELT, JWT ;
NORDE, W ;
LYKLEMA, J .
COLLOIDS AND SURFACES B-BIOINTERFACES, 1995, 5 (1-2) :11-23
[7]   THE PHYSICAL AND FUNCTIONAL-BEHAVIOR OF CAPTURE ANTIBODIES ADSORBED ON POLYSTYRENE [J].
BUTLER, JE ;
NI, L ;
NESSLER, R ;
JOSHI, KS ;
SUTER, M ;
ROSENBERG, B ;
CHANG, J ;
BROWN, WR ;
CANTARERO, LA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 150 (1-2) :77-90
[8]  
CASS T, 1998, IMMOBILIZED BIOMOLEC
[9]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[10]   Immobilization and stabilization of biomaterials for biosensor applications [J].
D'Souza, SF .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2001, 96 (1-3) :225-238