Separation and preconcentration of inorganic arsenic species in natural water samples with 3-(2-aminoethylamino) propyltrimethoxysilane modified ordered mesoporous silica micro-column and their determination by inductively coupled plasma optical emission spectrometry

被引:103
作者
Chen, Dahui [1 ,2 ]
Huang, Chaozhang [1 ]
He, Man [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[2] Wenzhou Med Coll, Dept Pharm, Wenzhou 325035, Peoples R China
关键词
Ordered mesoporous silica; Solid phase extraction (SPE); Inorganic arsenic speciation; AAPTS; ICP-OES; HYDRIDE GENERATION; SPECIATION ANALYSIS; ONLINE SEPARATION; CAPILLARY MICROEXTRACTION; EXTRACTION; SYSTEM; AS(III); YEAST; AS(V); ACID;
D O I
10.1016/j.jhazmat.2008.09.022
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
A simple and sensitive method using micro-column packed with 3-(2-aminoethylamino) propyltrimethoxysilane (AAPTS) modified ordered mesoporous silica combined with inductively coupled plasma optical emission spectrometry (ICP-OES) for the speciation of inorganic arsenic (As(III) and As(V)) has been developed. The adsorption behaviors of As(III) and As(V) on AAPTS modified ordered mesoporous silica were investigated. It was found that As(V) can be selectively adsorbed on the micro-column within pH of 3-9, while As(III) could not be retained in the studied pH range and passed through the micro-column directly. Total inorganic arsenic was extracted after the oxidation of As(III) to As(V) with 50.0 mu mol L-1 KMnO4. The assay of As(III) was based on subtracting As(V) from total As. The effect of various parameters on the separation/preconcentration of As(III) and As(V) have been investigated and the optimal experimental conditions were established. The adsorption capacity of AAPTS modified ordered mesoporous silica for As(V) was found to be 10.3 mg g(-1). The detection limit of the method for As(V) was 0.05 mu g L-1 with an enrichment factor of 100, and the relative standard deviation (R.S.D.) was 5.7% (n = 7, C = 1.0 mu g L-1). In order to validate the developed method. a certified reference material GSBZ50004-88 environmental water sample was analyzed and the determined values were in good agreement with the certified values. The proposed method was successfully applied to the speciation analysis of inorganic arsenic in natural water samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1146 / 1151
页数:6
相关论文
共 33 条
[1]
Determination of arsenic(III) and total inorganic arsenic in water samples using an on-line sequential insertion system and hydride generation atomic absorption spectrometry [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
ANALYTICA CHIMICA ACTA, 2005, 547 (02) :237-242
[2]
Determination of arsenic(III) by flow injection solid phase extraction coupled with on-line hydride generation atomic absorption spectrometry using a PTFE turnings-packed micro-column [J].
Anthemidis, Aristidis N. ;
Martavaltzoglou, Evdoxia K. .
ANALYTICA CHIMICA ACTA, 2006, 573 :413-418
[3]
Arsenic - a review. - Part 1: Occurrence, toxicity, speciation, mobility [J].
Bissen, M ;
Frimmel, FH .
ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 2003, 31 (01) :9-18
[4]
Inorganic arsenic speciation in various water samples with GFAAS using coprecipitation [J].
Elci, Latif ;
Divrikli, Uemit ;
Soylak, Mustafa .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (10) :711-723
[5]
On-line arsenic co-precipitation on ethyl vinyl acetate turning-packed mini-column followed by hydride generation-ICP OES determination [J].
Gil, R. A. ;
Ferrua, N. ;
Salonia, J. A. ;
Olsina, R. A. ;
Martinez, L. D. .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 143 (1-2) :431-436
[6]
Simultaneous separation and speciation of inorganic As(III)/As(V) and Cr(III)/Cr(VI) in natural waters utilizing capillary microextraction on ordered mesoporous Al2O3 prior to their on-line determination by ICP-MS [J].
Hu, Wenling ;
Zheng, Fei ;
Hu, Bin .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 151 (01) :58-64
[7]
Simultaneous speciation of inorganic arsenic and antimony in natural waters by dimercaptosuccinic acid modified mesoporous titanium dioxide micro-column on-line separation and inductively coupled plasma optical emission spectrometry determination [J].
Huang, Chaozhang ;
Hu, Bin ;
Jiang, Zucheng .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (05) :454-460
[8]
Effects of pH and competing anions on the speciation of arsenic in fixed ionic strength solutions by solid phase extraction cartridges [J].
Impellitteri, CA .
WATER RESEARCH, 2004, 38 (05) :1207-1214
[9]
Arsenic: Occurrence, toxicity and speciation techniques [J].
Jain, CK ;
Ali, I .
WATER RESEARCH, 2000, 34 (17) :4304-4312
[10]
Application of thiophene-2-carbaldehyde-modified mesoporous silica as a new sorbent for separation and preconcentration of palladium prior to inductively coupled plasma atomic emission spectrometric determination [J].
Jamali, Mohammad Reza ;
Assadi, Yaghoub ;
Shemirani, Farzaneh ;
Salavati-Niasari, Masoud .
TALANTA, 2007, 71 (04) :1524-1529