Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz

被引:117
作者
Dimbylow, PJ [1 ]
机构
[1] Natl Radiol Protect Board, Didcot OX11 0RQ, Oxon, England
关键词
D O I
10.1088/0031-9155/47/16/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Finite-difference time-domain (FDTD) calculations of whole-body averaged specific energy absorption rate (SAR) have been performed from 100 MHz to 3 GHz at the basic 2 mm resolution of the voxel (volume pixel) model NORMAN without any rescaling to larger cell sizes. The reduction in the voxel size from previous work allows SAR to be calculated at higher frequencies. Additionally, the calculations have been extended down to 10 MHz, covering the whole-body resonance regions at a resolution of 4 mm. As well as for the adult phantom, SAR values are calculated for scaled versions representing 10-, 5- and 1-year-old children for both grounded and isolated conditions. External electric field levels are derived from limits of whole-body averaged SAR and localized SAR in the ankle, and compared with NRPB investigation levels and ICNIRP reference levels. The ICNIRP field reference levels alone would not provide a conservative estimate of the localized SAR exposure in the leg for grounded conditions. It would be necessary to invoke the secondary reference level on limb current to provide compliance with basic restrictions on localized SAR averaged over 10 g.
引用
收藏
页码:2835 / 2846
页数:12
相关论文
共 19 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]   A PERFECTLY MATCHED LAYER FOR THE ABSORPTION OF ELECTROMAGNETIC-WAVES [J].
BERENGER, JP .
JOURNAL OF COMPUTATIONAL PHYSICS, 1994, 114 (02) :185-200
[3]   FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz [J].
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (03) :479-490
[4]   The calculation of localised SAR in a 2 mm resolution anatomically realistic model of the lower leg [J].
Dimbylow, PJ .
RADIATION PROTECTION DOSIMETRY, 1997, 72 (3-4) :321-326
[5]  
DIMBYLOW PJ, 1996, P INT WORKSH VOX PHA, P1
[6]  
Durney CH, 1986, RADIO FREQUENCY RAD, V4th
[7]   The dielectric properties of biological tissues .1. Literature survey [J].
Gabriel, C ;
Gabriel, S ;
Corthout, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2231-2249
[8]  
GABRIEL C, 1995, COMPILATION DIELECTR
[9]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[10]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293