Artificial neural networks and partial least squares regression for pseudo-first-order with respect to the reagent multicomponent kinetic-spectrophotometric determinations

被引:46
作者
Blanco, M
Coello, J
Iturriaga, H
Maspoch, S
Redon, M
Villegas, N
机构
关键词
artificial neural network; partial feast squares; butylamine-benzylamine mixture resolution; kinetic mixture resolution; salicylaldehyde;
D O I
10.1039/an9962100395
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Partial least squares (PLS) regression and an artificial neural network (ANN) were tested as calibration procedures for the kinetic-spectrophotometric determination of binary mixtures when the concentration of the reagent is much lower than the concentration of the analytes, The two calibration methods were first applied to computer-simulated kinetic-spectrophotometric data. The spectra of the reaction products (P-1, P-2) were represented by Gaussian bands with the same bandwidth and the effect of spectral overlap and experimental noise was studied, If both spectra are identical, the mixture cannot be resolved, However, if they are not, then it is possible to quantify simultaneously both analytes by measuring the absorbance at several wavelengths and times, It was found that the precision of the results depends fundamentally on the noise level in the rate constants, Both mathematical procedures were applied to the determination of benzylamine-butylamine mixtures using saticylaldehyde as chromogenic reagent, ANNs outperformed the PLS results giving a relative standard error of prediction of about 4% for the whole set of mixtures.
引用
收藏
页码:395 / 400
页数:6
相关论文
共 27 条
  • [1] [Anonymous], 1989, MULTIVARIATE CALIBRA
  • [2] CONTROL ANALYSIS OF A PHARMACEUTICAL PREPARATION BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY - A COMPARATIVE-STUDY OF A SPINNING MODULE AND FIBER OPTIC PROBE
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    DELAPEZUELA, C
    RUSSO, E
    [J]. ANALYTICA CHIMICA ACTA, 1994, 298 (02) : 183 - 191
  • [3] KINETIC SPECTROPHOTOMETRIC METHOD FOR ANALYZING MIXTURES OF METAL-IONS BY STOPPED-FLOW INJECTION-ANALYSIS USING PARTIAL LEAST-SQUARES REGRESSION
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    RIBA, J
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (18) : 2905 - 2911
  • [4] KINETIC SPECTROPHOTOMETRIC DETERMINATION OF GA(III)-AL(III) MIXTURES BY STOPPED-FLOW INJECTION-ANALYSIS USING PRINCIPAL COMPONENT REGRESSION
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    RIBA, J
    ROVIRA, E
    [J]. TALANTA, 1993, 40 (02) : 261 - 267
  • [5] PARTIAL LEAST-SQUARES REGRESSION FOR MULTICOMPONENT KINETIC DETERMINATIONS IN LINEAR AND NONLINEAR-SYSTEMS
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    REDON, M
    [J]. ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) : 309 - 320
  • [6] BLANCO M, 1996, IN PRESS QUIM ANAL
  • [7] BLANCO M, 1995, ANAL CHEM, V67, P4473
  • [8] NONLINEAR MULTIVARIATE MAPPING OF CHEMICAL-DATA USING FEEDFORWARD NEURAL NETWORKS
    BLANK, TB
    BROWN, SD
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (21) : 3081 - 3089
  • [9] OPTIMAL MINIMAL NEURAL INTERPRETATION OF SPECTRA
    BORGGAARD, C
    THODBERG, HH
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (05) : 545 - 551
  • [10] *COMP AID MOD A S, 1993, UNSCRAMBLER US GUID