Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators

被引:121
作者
Burri, Haran [1 ]
Senouf, David [1 ]
机构
[1] Univ Hosp Geneva, Serv Cardiol, CH-1211 Geneva, Switzerland
来源
EUROPACE | 2009年 / 11卷 / 06期
关键词
Pacemaker; Implantable cardioverter defibrillator; Telemedicine; Remote monitoring; Remote follow-up; RESYNCHRONIZATION THERAPY SYSTEMS; REDUCE INAPPROPRIATE SHOCKS; CLINICAL MANAGEMENT; LEAD FAILURE; CRT-ICD; EFFICACY; DEVICES; DESIGN; TIME; CARE;
D O I
10.1093/europace/eup110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the era of communication technology, new options are now available for following-up patients implanted with pacemakers (PMs) and defibrillators (ICDs). Most major companies offer devices with wireless capabilities that communicate automatically with home transmitters, which then relay data to the physician, thereby allowing remote patient follow-up and monitoring. These systems are being widely used in the USA for remote follow-up, and have been more recently introduced in Europe, where their adoption is increasing. In this article, we describe the currently existing systems, review the available evidence in the literature regarding remote follow-up and monitoring of PMs and ICDs, and finally discuss some unresolved issues.
引用
收藏
页码:701 / 709
页数:9
相关论文
共 37 条
[1]  
[Anonymous], 2011, WIRELESS ICD PROGRAM
[2]   What evidence do we have to replace in-hospital implantable cardioverter clefibrillator follow-up? [J].
Brugada, P .
CLINICAL RESEARCH IN CARDIOLOGY, 2006, 95 (Suppl 3) :3-9
[3]   Trial design of the clinical evaluation of remote notification to reduce time to clinical decision: The Clinical evaluation Of remote NotificatioN to rEduCe Time to clinical decision (CONNECT) study [J].
Crossley, George ;
Boyle, Andrew ;
Vitense, Holly ;
Sherfesee, Lou ;
Mead, R. Hardwin .
AMERICAN HEART JOURNAL, 2008, 156 (05) :840-846
[4]   Automated left ventricular capture management [J].
Crossley, George H. ;
Mead, Hardwin ;
Kleckner, Karen ;
Sheldon, Todd ;
Davenport, Lynn ;
Harsch, Manya R. ;
Parikh, Purvee ;
Ramza, Brian ;
Fishel, Robert ;
Bailey, J. Russell .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (10) :1190-1200
[5]   Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients [J].
Fauchier, L ;
Sadoul, N ;
Kouakam, C ;
Briand, F ;
Chauvin, M ;
Babuty, D ;
Clementy, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 :S255-S259
[6]   Pacemakers and implantable cardiac defibrillators: Software radio attacks and zero-power defenses [J].
Halperin, Daniel ;
Clark, Shane S. ;
Fu, Kevin ;
Heydt-Benjamin, Thomas S. ;
Defend, Benessa ;
Kohno, Tadayoshi ;
Ransford, Benjamin ;
Morgan, Will ;
Maisel, William H. .
PROCEEDINGS OF THE 2008 IEEE SYMPOSIUM ON SECURITY AND PRIVACY, 2008, :129-+
[7]   Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator [J].
Heidbuchel, Hein ;
Lioen, Pieter ;
Foulon, Stefaan ;
Huybrechts, Wim ;
Ector, Joris ;
Wiliems, Rik ;
Ector, Hugo .
EUROPACE, 2008, 10 (03) :349-355
[8]   Remote interrogation and monitoring of implantable cardioverter defibrillators [J].
Joseph, GK ;
Wilkoff, BL ;
Dresing, T ;
Burkhardt, J ;
Khaykin, Y .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 11 (02) :161-166
[9]   Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems [J].
Jung, Werner ;
Rillig, Andreas ;
Birkemeyer, Ralf ;
Miljak, Tomislav ;
Meyerfeldt, Udo .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (01) :73-85
[10]   Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead [J].
Kallinen, Linda M. ;
Hauser, Robert G. ;
Lee, Ken W. ;
Almquist, Adrian K. ;
Katsiyiannis, William T. ;
Tang, Chuen Y. ;
Melby, Daniel P. ;
Gornick, Charles C. .
HEART RHYTHM, 2008, 5 (06) :775-779