Theoretical advantages and drawbacks of on-line, multidimensional liquid chromatography using multiple columns operated in parallel

被引:33
作者
Fairchild, Jacob N. [1 ]
Horvath, Krisztian [1 ,2 ]
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Univ Pannonia, Dept Analyt Chem, H-8200 Veszprem, Hungary
关键词
Two-dimensional liquid chromatography; Multidimensional chromatography; Parallel columns; RETENTION DATA; BAND PROFILES; PEAK-CAPACITY; 2-DIMENSIONAL SEPARATIONS; REPRODUCIBILITY; REPEATABILITY; C-18; 1ST-DIMENSION; RESOLUTION; MIXTURES;
D O I
10.1016/j.chroma.2009.06.085
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The theoretical advantages and drawbacks of using a multiple-, parallel column approach in on-line multi-dimensional liquid chromatography systems were investigated. Much time or peak capacity can be gained with the use of multiple parallel columns at the second-dimension while the aggregate time of separation increases only by the increment of the gradient time of the second-dimension. Multidimensional chromatographic systems are now used to perform many tasks ranging from routine, fast analyses to specialized, arduous separations. In this work,we focus on the advantages of a Multiple, parallel columns approach to on-line multidimensional liquid chromatography systems. Calculations of the achievable peak capacities were made as functions of the number of columns operated in parallel. Increasing the number of second-dimension columns from one to two or three causes the largest increase in peak capacity with only a slight increase of aggregate time. We also present some practical aspects to consider when attempting multidimensional separations with multiple columns operated in parallel. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:6210 / 6217
页数:8
相关论文
共 50 条
[1]   Comprehensive two-dimensional liquid chromatography separations of pharmaceutical samples using dual Fused-Core columns in the 2nd dimension [J].
Alexander, Anthony J. ;
Ma, Lianjia .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) :1338-1345
[2]   Development of different comprehensive two dimensional systems for the separation of phenolic antioxidants [J].
Cacciola, Francesco ;
Jandera, Pavel ;
Blahova, Eva ;
Mondello, Luigi .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (16) :2500-2513
[3]   Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (02) :461-473
[4]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569
[5]   Approaches to comprehensive multidimensional liquid chromatography systems [J].
Fairchild, Jacob N. ;
Horvath, Krisztian ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) :1363-1371
[6]   Identification of the factors that influence the reproducibility of chromatographic retention data [J].
Felinger, A ;
Kele, M ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :23-48
[7]   Comprehensive two-dimensional liquid chromatography applying two parallel columns in the second dimension [J].
Francois, Isabelle ;
de Villiers, Andre ;
Tienpont, Bart ;
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) :33-42
[8]   ULTRASELECTIVITY THROUGH COLUMN SWITCHING AND MODE SEQUENCING IN LIQUID-CHROMATOGRAPHY - REVIEW [J].
FREEMAN, DH .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :2-5
[10]   TWO-DIMENSIONAL SEPARATIONS - CONCEPT AND PROMISE [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :1258-&