Elution of gentamicin and vancomycin from polymethylmethacrylate beads and hip spacers in vivo

被引:164
作者
Anagnostakos, Konstantinos [1 ]
Wilmes, Philippe [1 ]
Schmitt, Eduard [1 ]
Kelm, Jens [1 ]
机构
[1] Univ Saarland, Klin Orthopadie & Orthopad Chirurg, Homburg, Germany
关键词
ACRYLIC BONE-CEMENT; 2-STAGE REVISION; PMMA BEADS; ARTHROPLASTY; TOBRAMYCIN; ANTIBIOTICS; PROSTHESIS; INFECTION; INVITRO; RELEASE;
D O I
10.3109/17453670902884700
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background and purpose Late infections after total hip arthroplasty are still a problem. Treatment procedures include resection arthroplasty with implantation of antibiotic-loaded beads or implantation of an antibiotic-impreganted spacer. However, little is known about antibiotic elution from bone cement beyond the first 2-3 postoperative days in humans. Methods 17 hip spacers (80g PMMA, 1g gentamicin, and 4 g vancomycin) and 11 chains (40 g PMMA, 0.5 g gentamicin, and 2 g vancomycin) in 28 patients were studied. The release of both agents was measured in the drainage fluid on a daily basis. The drains were left in situ until less than 50 mL was produced per day. The elution of both antibiotics was determined by fluorescence polarization immunoassay. Systemic antibiotics were given postoperatively according to antibiogram. If possible, no gentamicin or vancomycin was given. Results Peak mean concentrations from beads and spacers were reached for gentamicin (1,160 (12-371) g/mL and 21 (0.7-39) g/mL, respectively) and for vancomycin (80 (21-198) g/mL and 37 (3.3-72) g/mL) on day 1. The last concentrations to be determined were 3.7 g/mL gentamicin and 23 g/mL vancomycin in the beads group after 13 days, and 1.9 g/mL gentamicin and 6.6 g/mL vancomycin in the spacer group after 7 days. Between the fifth and seventh day, an intermittent increase in elution of vancomycin from both beads and spacers and of gentamicin from spacers was noticed. No renal or hepatic dysfunction was observed. Interpretation Beads showed higher elution characteristics in vivo than the spacers due to their larger surface area; however, a great amount of inter-subject variability was seen for both beads and spacers. The inferior elution properties of spacers emphasize the importance of additional systemic antibiotics for this treatment procedure during the postoperative period. Future studies should clarify whether the dose of antibiotics or length of antibiotic therapy may be reduced in the case of bead implantation, without jeopardizing the control of infection.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 21 条
[1]
ADAMS K, 1992, CLIN ORTHOP RELAT R, P244
[2]
In vitro evaluation of antibiotic release from and bacteria growth inhibition by antibiotic-loaded acrylic bone cement spacers [J].
Anagnostakos, K ;
Kelm, J ;
Regitz, T ;
Schmitt, E ;
Jung, W .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) :373-378
[3]
Antibiotic-impregnated PMMA hip spacers -: Current status [J].
Anagnostakos, Konstantinos ;
Furst, Oliver ;
Kelm, Jens .
ACTA ORTHOPAEDICA, 2006, 77 (04) :628-637
[4]
BUCHHOLZ HW, 1970, CHIRURG, V41, P511
[5]
EFFECT OF POLYMETHYLMETHACRYLATE AND ANTIBIOTIC COMBINATIONS ON BACTERIAL VIABILITY - INVITRO AND PRELIMINARY INVIVO STUDY [J].
CHAPMAN, MW ;
HADLEY, WK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) :76-81
[6]
Pharmacokinetics, uses, and limitations of vancomycin-loaded bone cement [J].
Chohfi, M ;
Langlais, F ;
Fourastier, J ;
Minet, J ;
Thomazeau, H ;
Cormier, M .
INTERNATIONAL ORTHOPAEDICS, 1998, 22 (03) :171-177
[7]
High concentration and bioactivity of vancomycin and aztreonam eluted from Simplex™ cement spacers in two-stage revision of infected hip implants:: A study of 46 patients at an average follow-up of 107 days [J].
Hsieh, Pang-Hsin ;
Chang, Yu-Han ;
Chen, Shih-Hao ;
Ueng, Steve W. N. ;
Shih, Chun-Hsiung .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (08) :1615-1621
[8]
Two-stage revision hip arthroplasty for infection: Comparison between the interim use of antibiotic-loaded cement beads and a spacer prosthesis [J].
Hsieh, PH ;
Shih, CH ;
Chang, YH ;
Lee, MS ;
Shih, HN ;
Yang, WE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09) :1989-1997
[9]
Isiklar Z U, 1999, Bull Hosp Jt Dis, V58, P79
[10]