A pneumatically actuated full in-channel microvalve with MOSFET-like function in fluid channel networks

被引:50
作者
Takao, H [1 ]
Ishida, M [1 ]
Sawada, K [1 ]
机构
[1] Toyohashi Univ Technol, Dept Elect & Elect Engn, Toyohashi, Aichi 4418580, Japan
关键词
flow control; fluid power; micro fluidic system; MOSFET; pneumatic microvalve;
D O I
10.1109/JMEMS.2002.803414
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a pneumatically actuated silicon microvalve applicable to integrated microfluidic systems is presented. All the ports of this microvalve are in-channel, and connectable to any surface fluid channels in microfluidic systems. This microvalve controls fluid flow by means of the controlled gap between glass and silicon diaphragm actuated by a control pressure. In addition, the diaphragm is also deformed by the outlet pressure of the microvalve. Due to the feature, this microvalve shows saturation of flow rate like MOSFET's operated at saturation region. The fabricated microvalve device was evaluated especially focusing on analogous relationship between MOSFET and the microvalve. Fluids such as air and DI-water were well controlled by the control pressure. Fluid starts to flow in the microvalve when the control pressure exceeds its "threshold pressure." Hysteresis due to sticking of diaphragm was not observed in the characteristics. Air flow rate of the microvalve was gradually saturated with the increasing of the outlet pressure as expected. Through the evaluation, analogous relationship between this microvalve and MOSFET has been experimentally demonstrated. This microvalve can be used as not only flow control devices in micro fluidic systems but also as active devices in micro pneumatic circuits like transistor devices.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 11 条
[1]  
BOSH D, 1993, SENSOR ACTUAT A-PHYS, V37, P684
[2]   Design, fabrication, and testing of a bistable electromagnetically actuated microvalve [J].
Capanu, M ;
Boyd, JG ;
Hesketh, PJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (02) :181-189
[3]  
IKUTA K, 2001, 11 INT C SOL STAT SE, P916
[4]  
Nakagawa S., 1990, Proceedings. IEEE Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots (Cat. No.90CH2832-4), P89, DOI 10.1109/MEMSYS.1990.110255
[5]   Partly disposable three-way microvalve for a medical micro total analysis system (μTAS) [J].
Ohori, T ;
Shoji, S ;
Miura, K ;
Yotsumoto, A .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 64 (01) :57-62
[6]  
Rich CA, 1999, PROC IEEE MICR ELECT, P130
[7]  
Shoji S, 1998, TOP CURR CHEM, V194, P163
[8]  
TAKAO H, 2001, 11 INT C SOL STAT SE, P946
[9]   Development of a MEMS microvalve array for fluid flow control [J].
Vandelli, N ;
Wroblewski, D ;
Velonis, M ;
Bifano, T .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1998, 7 (04) :395-403
[10]  
Vieider C., 1995, 8th International Conference on Solid-State Sensors and Actuators and Eurosensors IX. Digest of Technical Papers (IEEE Cat. No.95TH8173), P284