Cloud point extraction and graphite furnace atomic absorption spectrometry determination of manganese(II) and iron(III) in water samples

被引:71
作者
Liang, Pei [1 ]
Sang, Hongbo [1 ]
Sun, Zhimei [1 ]
机构
[1] Cent China Normal Univ, Coll Chem, Minist Educ, Key Lab Pesticide & Chem Biol, Wuhan 430079, Peoples R China
关键词
cloud point extraction; graphite furnace atomic absorption spectrometry; manganese(II); iron(III);
D O I
10.1016/j.jcis.2006.09.006
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cloud point extraction (CPE) was applied as a preconcentration step prior to graphite furnace atomic absorption spectrometry (GFAAS) determination of manganese(II) and iron(III) in water samples. After complexation with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), the analytes could be quantitatively extracted to the phase rich in the surfactant p-octylpolyethyleneglycolphenylether (Triton X-100) and be concentrated, then determined by GFAAS. The parameters affecting the extraction efficiency, such as solution pH, concentration of PMBP and Triton X-100, equilibration temperature and time, were investigated in detail. Under the optimum conditions, preconcentration of 10 ml of sample solution permitted the detection of 0.02 ng ml(-1) of Mn(II) and 0.08 ng ml(-1) of Fe(III) with enrichment factors of 31 and 25 for Mn(II) and Fe(III), respectively. The proposed method was applied to determination of trace manganese(II) and iron(III) in water samples with satisfactory results. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:486 / 490
页数:5
相关论文
共 38 条
[1]   Preconcentration extractive separation, speciation and spectrometric determination of iron(III) in environmental samples [J].
Akl, MA .
MICROCHEMICAL JOURNAL, 2003, 75 (03) :199-209
[2]   Simultaneous preconcentration and speciation of iron(II) and iron(III) in water samples by 2-mercaptobenzimidazole-silica gel sorbent and flow injection analysis system [J].
Bagheri, H ;
Gholami, A ;
Najafi, A .
ANALYTICA CHIMICA ACTA, 2000, 424 (02) :233-242
[3]   The use of Agrobacterium tumefacients immobilized on Amberlite XAD-4 as a new biosorbent for the column preconcentration of iron(III), cobalt(II), manganese(II) and chromium(III) [J].
Baytak, S ;
Türker, AR .
TALANTA, 2005, 65 (04) :938-945
[4]  
Benkhedda I, 1999, J ANAL ATOM SPECTROM, V14, P957
[5]   A pre-concentration procedure using cloud point extraction for the determination of manganese in saline effluents of a petroleum refinery by flame atomic absorption spectrometry [J].
Bezerra, MD ;
Conceiçao, ALB ;
Ferreira, SLC .
MICROCHIMICA ACTA, 2006, 154 (1-2) :149-152
[6]   Cloud point extraction as a procedure of separation and pre-concentration for metal determination using spectroanalytical techniques: A review [J].
Bezerra, MD ;
Arruda, MAZ ;
Ferreira, SLC .
APPLIED SPECTROSCOPY REVIEWS, 2005, 40 (04) :269-299
[7]   Cloud point extraction as a preconcentration step prior to capillary electrophoresis [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Domínguez-Alvarez, J ;
Hernández-Méndez, J .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2468-2474
[8]   Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Xiao, SM ;
Wu, XH ;
Fang, KM ;
Liu, WH .
TALANTA, 2005, 67 (05) :992-996
[9]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[10]   Organic solvent-soluble membrane filters for the preconcentration and spectrophotometric determination of iron(II) traces in water with Ferrozine [J].
Chen, Y ;
Ding, CM ;
Zhou, TZ ;
Qi, DY .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (01) :119-120