Development of a 4-D digital mouse phantom for molecular imaging research

被引:331
作者
Segars, WP
Tsui, BMW
Frey, EC
Johnson, GA
Berr, SS
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
[2] Duke Univ, Duke Ctr In Vivo Microscopy, Durham, NC USA
[3] Univ Virginia, Dept Radiol, Charlottesville, VA USA
[4] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
关键词
phantom; simulation; single-photon emission computed tomography; computed tomography;
D O I
10.1016/j.mibio.2004.03.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: We develop a realistic and flexible 4-D digital mouse phantom and investigate its usefulness in molecular imaging research. METHODS: Organ shapes were modeled with non-uniform rational B-spline (NURBS) surfaces based on high-resolution 3-D magnetic resonance microscopy (MRM) data. Cardiac and respiratory motions were modeled based on gated magnetic resonance imaging (MRI) data obtained from normal mice. Pilot simulation studies in single-photon emission computed tomography (SPELT) and X-ray computed tomography (CT) were performed to demonstrate the utility of the phantom. RESULTS: NURBS are an efficient and flexible way to accurately model the anatomy and cardiac and respiratory motions for a realistic 4-D digital mouse phantom. The phantom is capable of producing realistic molecular imaging data from which imaging devices and techniques can be evaluated. CONCLUSION: The phantom provides a unique and useful tool in molecular imaging research. It can be used in the development of new imaging instrumentation, image acquisition strategies, and image processing and reconstruction methods. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 19 条
[1]  
BERR SS, 2001, INT SOC MAGN RES MED
[2]  
EPSTEIN FH, 2002, BLACK BLOOD MYOCARDA
[3]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[4]  
FENN WO, 1964, RESP HDB PHYSL 3, V1
[5]  
Green EL, 1966, STAFF JACKSON LAB BI
[6]   3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET [J].
HOFFMAN, EJ ;
CUTLER, PD ;
DIGBY, WM ;
MAZZIOTTA, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :616-620
[7]   Morphologic phenotyping with MR microscopy: The visible mouse [J].
Johnson, GA ;
Cofer, GP ;
Gewalt, SL ;
Hedlund, LW .
RADIOLOGY, 2002, 222 (03) :789-793
[8]  
MCNEIL R, 1989, RHINOCEROS
[9]  
MOODY D, 1997, 14 ANN M AM ASS CLIN
[10]  
Peterson R, 1998, MANKIND QUART, V39, P121