Normal variation of vertebral artery on CT angiography and its implications for diagnosis of acquired pathology

被引:51
作者
Sanelli, PC [1 ]
Tong, S [1 ]
Gonzalez, RG [1 ]
Eskey, CJ [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
arteries; vertebral; computed tomograph angiography;
D O I
10.1097/00004728-200205000-00027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: CT angiograpliy (CTA) is rapidly becoming a popular tool for the evaluation of cerebrovascular diseases. Noninvasive diagnosis of vertebral artery pathology using CTA relies in part on diminished vertebral artery size or eccentric position relative to the transverse foramen. However, normal variation of the vertebral artery on CT has not been systematically described. Method: Patients younger than 40 years who underwent CTA for reasons other than evaluation of vertebral artery disease were studied. Area measurements of the vertebral artery and the transverse foramen Were performed by three radiologists. Variance component analysis was performed. Results: There is marked variation in the size of the vertebral artery relative to the transverse foramen, with the vertebral artery occupying 8-85% of the foramen. In many patients, marked asymmetry in relative vertebral artery size and position was observed. This asymmetry would often vary markedly from le cl to level within the same patient. Conclusion: Vertebral artery size and position in the transverse foramina vary markedly in normal young subjects. These normal variations must be considered when evaluating vertebral artery pathology on CT angiograms.
引用
收藏
页码:462 / 470
页数:9
相关论文
共 27 条
[1]   VERTEBRAL ARTERIES (V1 AND V2 SEGMENTS) [J].
ARGENSON, C ;
FRANCKE, JP ;
SYLLA, S ;
DINTIMILLE, H ;
PAPASIAN, S .
ANATOMIA CLINICA, 1979, 2 (01) :29-41
[2]  
Box GEP., 1978, Statistics for experimenters
[3]   EFFECT OF VOLUME AND RATE OF CONTRAST-MEDIUM INJECTION ON INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHIC CONTRAST-MEDIUM CURVES [J].
BURBANK, FH ;
BRODY, WR ;
BRADLEY, BR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (02) :308-315
[4]   CT ANGIOGRAPHY OF THE COMMON CAROTID-ARTERY BIFURCATION - COMPARISON BETWEEN 2 TECHNIQUES AND CONVENTIONAL ANGIOGRAPHY [J].
CASTILLO, M ;
WILSON, JD .
NEURORADIOLOGY, 1994, 36 (08) :602-604
[5]  
CAVDAR S, 1989, ACTA ANAT, V135, P236
[6]   EVOLUTION OF DOLICHOECTASIA OF THE VERTEBROBASILAR SYSTEM AS EVIDENCED BY SERIAL COMPUTED-TOMOGRAPHY [J].
CORKILL, G ;
SARWAR, M ;
VIRAPONGSE, C .
SURGICAL NEUROLOGY, 1982, 18 (04) :262-266
[7]   CAROTID-ARTERY STENOSIS - A PROSPECTIVE COMPARISON OF CT ANGIOGRAPHY AND CONVENTIONAL ANGIOGRAPHY [J].
CUMMING, MJ ;
MORROW, IM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :517-523
[8]  
GABRIELSEN TO, 1969, ACTA RADIOL DIAGN, V9, P285
[9]   Surgical anatomy of the vertebral arteries [J].
Heary, RF ;
Albert, TJ ;
Ludwig, SC ;
Vaccaro, AR ;
Wolansky, LJ ;
Leddy, TP ;
Schmidt, RR .
SPINE, 1996, 21 (18) :2074-2080
[10]  
Holden A, 1996, Australas Radiol, V40, P65, DOI 10.1111/j.1440-1673.1996.tb00348.x