Small cryostem for operation of visible light photon counters (VLPC)

被引:2
作者
Baumbaugh, B
Bishop, J
Biswas, N
Coney, L
Marchant, J
Masterson, E
Ruchti, R
Stavish, T
Warchol, J
Wayne, M
机构
[1] University of Notre Dame, Department of Physics, Notre Dame
关键词
D O I
10.1109/23.507214
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have designed, constructed, and operated a small cryostem which supports the operation of 32 channels of Visible Light Photon Counters (HISTE-IV VLPCs). The VLPCs are situated within a small enclosure which can be lowered into a 30-100 liter dewar. The enthalpy of the boil-off helium keeps the VLPCs cold, and allows the system to be operated with stability for many days within the desired temperature range of 6.0K-7.5K. The cryostem is instrumented with clear fiber waveguides which transport the light from an optical connector situated at the top of the cryostem and outside of the dewar to the photosensors at cryogenic temperatures within the dewar. Electrical signals from the VLPCs are amplified at room temperature using QPA02 preamplifiers. Details of design and performance are reviewed.
引用
收藏
页码:1741 / 1745
页数:5
相关论文
共 7 条
[1]   PERFORMANCE OF A LARGE-SCALE SCINTILLATING-FIBER TRACKER USING VLPC READOUT [J].
ADAMS, D ;
ADAMS, M ;
BAUMBAUGH, B ;
BERTRAM, I ;
BROSS, A ;
CASEY, D ;
CHANG, S ;
CHUNG, M ;
COOPER, C ;
CRETSINGER, C ;
DEMINA, R ;
FANOURAKIS, G ;
FERBEL, T ;
GRUNENDAHL, S ;
HINSON, J ;
HOWELL, B ;
JOHARI, H ;
KANG, JS ;
KIM, CL ;
KIM, SK ;
KOLTICK, D ;
LOBKOWICZ, F ;
MARGULIES, S ;
MOROMISATO, J ;
NARAIN, M ;
PARK, CH ;
PARK, YM ;
REUCROFT, S ;
RUCHTI, R ;
SOLOMON, J ;
VONGOELER, E ;
WARCHOL, J ;
WAYNE, M ;
WON, E ;
YU, YS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :401-406
[2]  
ADAMS D, 1995, NUCL PHYS B, V44, P340
[3]  
MARGULIES S, 1995, P SOC PHOTO-OPT INS, V2551, P10, DOI 10.1117/12.218630
[4]   PHOTON-COUNTING SOLID-STATE PHOTOMULTIPLIER [J].
PETROFF, MD ;
STAPELBROEK, MG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :158-162
[5]   HIGH-ENERGY PARTICLE TRACKING USING SCINTILLATING FIBERS AND SOLID-STATE PHOTOMULTIPLIERS [J].
PETROFF, MD ;
ATAC, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :163-164
[6]  
RUCHTI RC, 1995, P SOC PHOTO-OPT INS, V2551, P17, DOI 10.1117/12.218640
[7]   A HIGH-SPEED, LOW-NOISE ASIC PREAMPLIFIER FOR SILICON STRIP DETECTORS [J].
ZIMMERMAN, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :439-443