Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements

被引:22
作者
Debbins, JP [1 ]
Felmlee, JP [1 ]
Riederer, SJ [1 ]
机构
[1] MAYO CLIN,MAGNET RESONANCE LAB,ROCHESTER,MN 55905
关键词
phased array; surface coil; reconstruction; MRI; signal-to-noise ratio;
D O I
10.1002/mrm.1910380621
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multiple element surface coils are often used in clinical MRI to increase the image signal-to-noise ratio (S/N). Use of multi-coils typically requires increased net sampling bandwidth and data processing for each coil element, A phase-alignment technique is described which combines the signals from all coil elements before image reconstruction, greatly relaxing the technical requirements of the standard multicoil methods. Hardware and software implementations allow reduction of the reconstruction requirement to that of a single coil. The hardware implementation additionally allows a significant reduction in the net sampling bandwidth. The method is applicable to high speed MRI techniques, as demonstrated in phantoms and volunteers.
引用
收藏
页码:1003 / 1011
页数:9
相关论文
共 17 条
[1]   RECONSTRUCTIONS OF PHASE-CONTRAST, PHASED-ARRAY MULTICOIL DATA [J].
BERNSTEIN, MA ;
GRGIC, M ;
BROSNAN, TJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :330-334
[2]   MR-IMAGING OF THE ABDOMEN WITH A PHASED-ARRAY MULTICOIL - PROSPECTIVE CLINICAL-EVALUATION [J].
CAMPEAU, NG ;
JOHNSON, CD ;
FELMLEE, JP ;
RYDBERG, JN ;
BUTTS, RK ;
EHMAN, RL ;
RIEDERER, SJ .
RADIOLOGY, 1995, 195 (03) :769-776
[3]   A PHASED-ARRAY COIL FOR HUMAN CARDIAC IMAGING [J].
CONSTANTINIDES, CD ;
WESTGATE, CR ;
ODELL, WG ;
ZERHOUNI, EA ;
MCVEIGH, ER .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :92-98
[4]   Cardiac magnetic resonance fluoroscopy [J].
Debbins, JP ;
Riederer, SJ ;
Rossman, PJ ;
Grimm, RC ;
Felmlee, JP ;
Breen, JF ;
Ehman, RL .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :588-595
[5]   A real-time reconstruction system for magnetic resonance imaging [J].
Gmitro, AF ;
Ehsani, AR ;
Berchem, TA ;
Snell, RJ .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :734-740
[6]   TEMPORAL LOBES - SURFACE MR COIL PHASED-ARRAY IMAGING [J].
HAYES, CE ;
TSURUDA, JS ;
MATHIS, CM .
RADIOLOGY, 1993, 189 (03) :918-920
[7]   VOLUME IMAGING WITH MR PHASED-ARRAYS [J].
HAYES, CE ;
HATTES, N ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :309-319
[8]   PELVIC IMAGING WITH PHASED-ARRAY COILS - QUANTITATIVE ASSESSMENT OF SIGNAL-TO-NOISE RATIO IMPROVEMENT [J].
HAYES, CE ;
DIETZ, MJ ;
KING, BF ;
EHMAN, RL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :321-326
[9]  
KORESEC FR, 1996, MAGNET RESON MED, V36, P345
[10]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58