Measurement of orbital volume by a 3-dimensional software program:: An experimental study

被引:46
作者
Deveci, M
Öztürk, S
Sengezer, M
Pabuscu, Y
机构
[1] Gulhane Mil Med Acad, Dept Plast & Reconstruct Surg, Ankara, Turkey
[2] Gulhane Mil Med Acad, Dept Radiol, Ankara, Turkey
关键词
D O I
10.1053/joms.2000.6207
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study reports a simple method with high accuracy for determining orbital volume from computed tomography (CT) scans. Materials and Methods: The volume of 20 orbits was evaluated in 20 dry skulls by use of a 3-dimensional software program in General Electric High-Speed Advantage CT/I (Milwaukee, WI), and compared with the volume obtained by direct measurement using the water displacement method. Accuracy of volume measurement by this software program was assessed statistically by paired samples t-test, Results: The mean volume was found to be 28.37 mL +/- 2.15 by direct impression and 28.41 mL +/- 2.09 by the software program. Volume difference between the 2 methods averaged 0.93 +/- 1.08 mt for each orbit (P <.01). The correlation between the techniques was found to be high (r = 0.887, P <.01). There was no significant volume discrepancy between the 2 methods. Conclusion: Measurement by the technique described is an easy and accurate method of assessing the volume of the orbit, (C) 2000 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:645 / 648
页数:4
相关论文
共 12 条
[1]   ORBITAL VOLUME MEASUREMENTS IN ENOPHTHALMOS USING 3-DIMENSIONAL CT IMAGING [J].
BITE, U ;
JACKSON, IT ;
FORBES, GS ;
GEHRING, DG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1985, 75 (04) :502-507
[2]  
BRINK JA, 1995, RADIOL CLIN N AM, V33, P825
[3]   ORBITAL VOLUME MEASUREMENT IN THE MANAGEMENT OF PURE BLOWOUT FRACTURES OF THE ORBITAL FLOOR [J].
CHARTERIS, DG ;
CHAN, CH ;
WHITEHOUSE, RW ;
NOBLE, JL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (02) :100-102
[4]   An experimental investigation of the safe distance for internal orbital dissection [J].
Danko, I ;
Haug, RH .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (06) :749-752
[5]   THE ROLE OF ORBITAL WALL MORPHOLOGICAL PROPERTIES AND THEIR SUPPORTING STRUCTURES IN THE ETIOLOGY OF BLOW-OUT FRACTURES [J].
JO, A ;
RIZEN, V ;
NIKOLIC, V ;
BANOVIC, B .
SURGICAL AND RADIOLOGIC ANATOMY, 1989, 11 (03) :241-248
[6]   STUDIES ON ENOPHTHALMOS .2. THE MEASUREMENT OF ORBITAL INJURIES AND THEIR TREATMENT BY QUANTITATIVE COMPUTED-TOMOGRAPHY [J].
MANSON, PN ;
GRIVAS, A ;
ROSENBAUM, A ;
VANNIER, M ;
ZINREICH, J ;
ILIFF, N .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (02) :203-214
[7]   THE LONGITUDINAL ORBITAL CT PROJECTION - A VERSATILE IMAGE FOR ORBITAL ASSESSMENT [J].
MARSH, JL ;
GADO, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1983, 71 (03) :308-317
[8]  
McGurk M, 1992, Dentomaxillofac Radiol, V21, P70
[9]  
NGUYEN PN, 1992, CLIN PLAST SURG, V19, P87
[10]  
PEARL RM, 1992, CLIN PLAST SURG, V19, P99