Processing radio frequency ultrasound images: A robust method for local spectral features estimation by a spatially constrained parametric approach

被引:10
作者
Gorce, JM [1 ]
Friboulet, D
Dydenko, I
D'hooge, J
Bijnens, BH
Magnin, IE
机构
[1] Inst Natl Sci Appl, CITI, F-69621 Villeurbanne, France
[2] Catholic Univ Louvain, Dept Cardiol, B-3000 Louvain, Belgium
[3] Inst Natl Sci Appl, CREATIS, CNRS, UMR 5515,Res Unit,INSERM, F-69621 Villeurbanne, France
关键词
D O I
10.1109/TUFFC.2002.1159848
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Spectral estimation is a major component in studies aiming at characterizing biological tissues through the analysis of backscattered radio frequency (RE) ultrasonic signals and images. However, conventional spectral estimation techniques yield a well-known trade-off between spatial resolution and variance. The backscattered signals are stochastic by nature, so short-term local analysis results in a high variance of the estimates, which cannot efficiently be reduced through conventional spatial averaging. We address this issue by describing a spectral estimation technique that reduces the variance of the estimates (by smoothing the local estimates in spectrally homogeneous regions) while preserving spectral discontinuities (i.e., the smoothing is not performed across regions with different spectral contents). The proposed approach is set in a Bayesian framework and is based on local autoregressive (AR) estimation, constrained by smoothness priors. These smoothness priors are introduced through a Markov random field in which the associated potential functions are nonquadratic, allowing thereby to preserve discontinuity. The method is validated on simulated RF images and tested on echocardiographic images acquired in vivo. The results are compared to the estimates provided by the conventional Burg technique. These results clearly demonstrate the ability of the proposed approach to improve spectral estimation in terms of variance reduction and discontinuity detection.
引用
收藏
页码:1704 / 1719
页数:16
相关论文
共 47 条
[1]   APPLICATION OF AUTOREGRESSIVE SPECTRAL-ANALYSIS FOR ULTRASOUND ATTENUATION ESTIMATION - INTEREST IN HIGHLY ATTENUATING MEDIUM [J].
BALDEWECK, T ;
LAUGIER, P ;
HERMENT, A ;
BERGER, G .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (01) :99-110
[2]   ULTRASONIC B-SCANNING - A COMPUTER-SIMULATION [J].
BAMBER, JC ;
DICKINSON, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (03) :463-479
[3]  
BARBARESCO F, 1999, PSIP 99, P227
[4]  
BARBARESCO F, 1998, EUSIPCO 98, P621
[5]   DISTANCE MEASURES FOR SIGNAL-PROCESSING AND PATTERN-RECOGNITION [J].
BASSEVILLE, M .
SIGNAL PROCESSING, 1989, 18 (04) :349-369
[6]   ACQUISITION AND PROCESSING OF THE RADIOFREQUENCY SIGNAL IN ECHOCARDIOGRAPHY - A NEW GLOBAL APPROACH [J].
BIJNENS, B ;
HERREGODS, MC ;
NUYTS, J ;
VANDEWEGHE, G ;
SUETENS, P ;
VANDEWERF, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (02) :167-176
[7]  
BIJNENS B, 1997, THESIS KATHOLIEKE U
[8]  
Blake A., 1987, Visual Reconstruction
[9]   INSTRUMENT-INDEPENDENT ACOUSTIC BACKSCATTER COEFFICIENT IMAGING [J].
BOOTE, EJ ;
ZAGZEBSKI, JA ;
MADSEN, EL ;
HALL, TJ .
ULTRASONIC IMAGING, 1988, 10 (02) :121-138
[10]   Parametric (integrated backscatter and attenuation) images constructed using backscattered radio frequency signals (25-56 MHz) from human aortae in vitro [J].
Bridal, SL ;
Fornes, P ;
Bruneval, P ;
Berger, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :215-229