Measurement of sacroiliac joint dysfunction: A multicenter intertester reliability study

被引:18
作者
Freburger, JK
Riddle, DL
机构
[1] Univ N Carolina, Div Phys Therapy, Chapel Hill, NC 27599 USA
[2] Virginia Commonwealth Univ, Dept Phys Therapy, Richmond, VA USA
来源
PHYSICAL THERAPY | 1999年 / 79卷 / 12期
关键词
measurement; reliability; sacroiliac joint;
D O I
10.1093/ptj/79.12.1134
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. Previous research suggests that visual estimates of sacroiliac joint (SIJ) alignment are unreliable. The purpose of this sludy was to determine whether handheld calipers and an inclinometer could be used to obtain reliable measurements of SIJ alignment in subjects suspected of having SIJ dysfunction. Subjects. Seventy-three subjects, evaluated at 1 of 5 outpatient clinics, participated in the study. Methods. A total of 23 therapists, randomly paired for each subject, sen ed as examiners. The angle of inclination of each innominate was measured while the subject was standing. The position of the innominates relative to each other was then derived. An intraclass correlation coefficient (ICC), the standard error of measurement (SEM), and a kappa coefficient were calculated to examine the reliability; of the derived measurements. Results. The ICC was .27 the SEM was 5.4 degrees, and the kappa value was .18. Conclusion and Discussion. Measurements of SIJ alignment were unreliable. Therapists should consider procedures other than those that assess SIJ alignment when evaluating the SIJ.
引用
收藏
页码:1134 / 1141
页数:8
相关论文
共 22 条
[1]
*ACSM, 1995, ACSM GUID EX TEST PR
[2]
ANASTASI A, 1988, PSYCHOLOGICAL TESTIN
[3]
CHANGES IN INNOMINATE TILT AFTER MANIPULATION OF THE SACROILIAC JOINT IN PATIENTS WITH LOW-BACK PAIN - AN EXPERIMENTAL-STUDY [J].
CIBULKA, MT ;
DELITTO, A ;
KOLDEHOFF, RM .
PHYSICAL THERAPY, 1988, 68 (09) :1359-1363
[4]
Unilateral hip rotation range of motion asymmetry in patients with sacroiliac joint regional pain [J].
Cibulka, MT ;
Sinacore, DR ;
Cromer, GS ;
Delitto, A .
SPINE, 1998, 23 (09) :1009-1015
[5]
[6]
Conover W. J., 1980, PRACTICAL NONPARAMET
[7]
THE EFFECT OF IMPOSED LEG LENGTH DIFFERENCE ON PELVIC BONE SYMMETRY [J].
CUMMINGS, G ;
SCHOLZ, JP ;
BARNES, K .
SPINE, 1993, 18 (03) :368-373
[8]
FUNCTION AND PATHOMECHANICS OF THE SACROILIAC JOINT - A REVIEW [J].
DONTIGNY, RL .
PHYSICAL THERAPY, 1985, 65 (01) :35-44
[9]
MOVEMENTS IN SACROILIAC JOINTS DEMONSTRATED WITH ROENTGEN STEREOPHOTOGRAMMETRY [J].
EGUND, N ;
OLSSON, TH ;
SCHMID, H ;
SELVIK, G .
ACTA RADIOLOGICA-DIAGNOSIS, 1978, 19 (05) :833-846
[10]
Greenman PE., 1989, PRINCIPLES MANUAL ME