Mobile bearing or fixed bearing? A meta-analysis of outcomes comparing mobile bearing and fixed bearing bilateral total knee replacements

被引:28
作者
Bo, Zhan-dong [1 ]
Liao, Liang [1 ]
Zhao, Jin-min [1 ]
Wei, Qing-jun [1 ]
Ding, Xiao-fei [1 ]
Yang, Biao [1 ]
机构
[1] Guangxi Med Univ, Affiliated Hosp 1, Dept Orthoped Trauma & Hand Surg, Nanning 530021, Guangxi Provinc, Peoples R China
关键词
Mobile bearing; Fixed bearing; Total knee arthroplasty; Bilateral; Meta-analysis; FOLLOW-UP; CLINICAL-OUTCOMES; ROTATING-PLATFORM; ARTHROPLASTY; PROSTHESIS; MINIMUM; INSTABILITY; OSTEOLYSIS; PATIENT; YOUNG;
D O I
10.1016/j.knee.2013.10.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: To compare outcomes between mobile-bearing (MB) and fixed-bearing (FB) in bilateral total knee replacements. Methods: The MEDLINE, EMBASE and Cochrane Library databases were searched. Randomized controlled trials of bilateral total knee arthroplasty with one of each design implanted were identified. Weighted mean differences (WMDs) and pooled risk ratios (RRs) were calculated using fixed- or random-effects models. Results: Twelve studies were identified with a total of 807 patients and 1614 knees. All RCTs were of high quality with a low risk of bias. No statistical difference was found between MB and FB at 2- to 5-year follow-up in terms of America Knee Society score (WMD: -1.29, 95% CI: -5.65 to 3.06), pain score (WMD: -326,95% CI: -10.45 to 3.93), range of motion (WMD: -4.16,95% CI: -9.97 to 1.66), reoperation (RR: 1.00,95% CI: 0.28 to 3.60), and radiolucent lines (RR: 1.51, 95% CI: 0.70 to 3.24). The results were similar at 1-, 5- to 8-, or >8-year follow-up. Patient's satisfaction (RR: 0.85, 95% CI: 0.54 to 134), and complication (<= 2-year, RR: 0.55, 95% CI: 0.29 to 1.04; >2-year, RR: 1.0,95% CI = 0.73 to 138) also showed no difference between two groups. Conclusions: Based on this meta-analysis we are unable to detect the superiority of MB as compared to FB. More randomized trials with a larger sample size and longer follow-up are needed to evaluate these two kinds of prosthesis. (c) 2013 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:374 / 381
页数:8
相关论文
共 37 条
[1]
Introduction of a new mobile-bearing total knee prosthesis - Minimum three year follow-up of an RCT comparing it with a fixed-bearing device [J].
Beard, D. J. ;
Pandit, H. ;
Price, A. J. ;
Butler-Manuel, P. A. ;
Dodd, C. A. F. ;
Murray, D. W. ;
Goodfellow, J. W. .
KNEE, 2007, 14 (06) :448-451
[2]
A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years [J].
Bhan, S ;
Malhotra, R ;
Kiran, EK ;
Shukla, S ;
Bijjawara, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (10) :2290-2296
[3]
Chiu K Y, 2001, J Orthop Surg (Hong Kong), V9, P45
[4]
Chmell MJ, 1999, CLIN ORTHOP RELAT R, P54
[5]
Total knee replacement in young, active patients - Long-term follow-up and functional outcome [J].
Diduch, DR ;
Insall, JN ;
Scott, WN ;
Scuderi, GR ;
FontRodriguez, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (04) :575-582
[6]
EZZET KA, 1995, CLIN ORTHOP RELAT R, P86
[7]
Staged bilateral mobile-bearing and fixed-bearing total knee arthroplasty in the same patients: a prospective comparison of a posterior-stabilized prosthesis [J].
Hasegawa, Masahiro ;
Sudo, Akihiro ;
Uchida, Atsumasa .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (03) :237-243
[8]
Mobile bearings do not improve fixation in cemented total knee arthroplasty [J].
Henricson, Anders ;
Dalen, Tore ;
Nilsson, Kjell G. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) :114-121
[9]
A 5 to 8 year follow-up study of the Rotaglide mobile bearing total knee arthroplasty [J].
Hudd, Alastair ;
Kunasingam, Kumar ;
Ricketts, David ;
Bush, John .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) :675-678
[10]
Jacobs W., 2004, COCHRANE DB SYST REV, DOI [DOI 10.1002/14651858.CD003130.PUB2, 10.1002/14651858.CD003130.pub2.]