Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters

被引:80
作者
Jenkins, Carly [1 ]
Chan, Jonathan [1 ]
Hanekom, Lizelle [1 ]
Marwick, Thomas H. [1 ]
机构
[1] Univ Queensland, St Lucia, Qld 4067, Australia
关键词
D O I
10.1016/j.echo.2006.04.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The availability of automated online software may increase the feasibility of real-time 3-dimensional (3D) echocardiography (3DE) for left ventricular (LV) volume calculation in clinical practice. We sought to compare offline and online approaches with magnetic resonance imaging (MRI). Methods. Patients who presented to the clinical laboratory for evaluation of LV parameters (n = 110, 94 men, age 63 +/- 10 years) were studied with 2-dimensional echocardiography, online and offline 3DE, and MRI. The 3DE measurements were obtained by a semiautomated LV border detection based on tracing (online) and edge detection (offline). MRI images were obtained using true free induction steady-state precession during breath hold, with measurement of 3D volumes and ejection fraction (EF). Results. All echocardiographic techniques underestimated LV volumes, but EF estimations were similar. The best correlation was between MRI versus offline 3DE. The correlation of online 3DE with MRI was significantly better than 2-dimensional echocardiography (end-diastolic volume (EDV) z = 4.2, end-systolic volume (ESV) z = 4.44, EF z = 4.32; all P <.01). However, correlation of offline 3DE with MRI was significantly better than online 3DE (EDV z = 2.57, P <.05; ESV z = 2.42, P <.05; EF z = 3.82, P <.01). Images were considered to be good quality (endocardium visualized in all walls) in 49 patients; discrepancies between online and offline 3DE and MRI were similar in good- and poor-quality images. Wall-motion abnormalities were present in 98 patients; discrepancies with MRI were similar in patients with and without abnormal wall motion. Conclusions: Online measurement of LV volumes is feasible and more accurate than with 2-dimensional echocardiography. Although the offline approach is more accurate, it is also more time-consuming.
引用
收藏
页码:1119 / 1128
页数:10
相关论文
共 17 条
[1]   Left ventricular dyssynchrony predicts response and prognosis after cardiac resynchronization therapy [J].
Bax, JJ ;
Bleeker, GB ;
Marwick, TH ;
Molhoek, SG ;
Boersma, E ;
Steendijk, P ;
van der Wall, EE ;
Schalij, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (09) :1834-1840
[2]   STATISTICS NOTES .1. CORRELATION, REGRESSION, AND REPEATED DATA [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1994, 308 (6933) :896-896
[3]   CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .2. CORRELATION BETWEEN SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6980) :633-633
[4]   ACC/AHA/ASE 2003 guideline update for the clinical application of Echocardiography: Summary article [J].
Cheitlin, MD ;
Armstrong, WF ;
Aurigemma, GP ;
Beller, GA ;
Bierman, FZ ;
Davis, JL ;
Douglas, PS ;
Faxon, DP ;
Gillam, LD ;
Kimball, TR ;
Kussmaul, WG ;
Pearlman, AS ;
Philbrick, JT ;
Rakowski, H ;
Thys, DM ;
Antman, EM ;
Smith, SC ;
Alpert, JS ;
Gregoratos, G ;
Anderson, JL ;
Hiratzka, LF ;
Faxon, DP ;
Hunt, SA ;
Fuster, V ;
Jacobs, AK ;
Gibbons, RJ ;
Russell, RO .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (10) :1091-1110
[5]   Effects of carvedilol on left ventricular remodeling after acute myocardial infarction -: The CAPRICORN echo substudy [J].
Doughty, RN ;
Whalley, GA ;
Walsh, HA ;
Gamble, GD ;
López-Sendón, J ;
Sharpe, N .
CIRCULATION, 2004, 109 (02) :201-206
[6]   Antiremodeling effect of long-term exercise training in patients with stable chronic heart failure results of the exercise in left ventricular dysfunction and chronic heart failure (ELVD-CHF) trial [J].
Giannuzzi, P ;
Temporelli, PL ;
Corrà, U ;
Tavazzi, L .
CIRCULATION, 2003, 108 (05) :554-559
[7]   ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS [J].
GOPAL, AS ;
SHEN, ZQ ;
SAPIN, PM ;
KELLER, AM ;
SCHNELLBAECHER, MJ ;
LEIBOWITZ, DW ;
AKINBOBOYE, OO ;
RODNEY, RA ;
BLOOD, DK ;
KING, DL .
CIRCULATION, 1995, 92 (04) :842-853
[8]   American Society of Echocardiography recommendations for use of echocardiography in clinical trials - A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Echocardiography in Clinical Trials [J].
Gottdiener, JS ;
Bednarz, J ;
Devereux, R ;
Gardin, J ;
Klein, A ;
Manning, WJ ;
Morehead, A ;
Kitzman, D ;
Oh, J ;
Quinones, M ;
Schiller, NB ;
Stein, JH ;
Weissman, NJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (10) :1086-1119
[9]   Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction [J].
Hibberd, MG ;
Chuang, ML ;
Beaudin, RA ;
Riley, MF ;
Mooney, MG ;
Fearnside, JT ;
Manning, WJ ;
Douglas, PS .
AMERICAN HEART JOURNAL, 2000, 140 (03) :469-475
[10]   Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data [J].
Jacobs, LD ;
Salgo, IS ;
Goonewardena, S ;
Weinert, L ;
Coon, P ;
Bardo, D ;
Gerard, O ;
Allain, P ;
Zamorano, JL ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
EUROPEAN HEART JOURNAL, 2006, 27 (04) :460-468