On-line monitoring of chromium(III) using a fast micromachined mixer/reactor and chemiluminescence detection

被引:62
作者
Xu, Y [1 ]
Bessoth, FG [1 ]
Eijkel, JCT [1 ]
Manz, A [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Zeneca Smithkline Beecham Ctr Analyt Sci, London SW7 2AY, England
关键词
D O I
10.1039/a908883k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast micromachined mixer/reactor was employed in a continuous flow injection set-up for the direct detection of chromium(III) in aqueous samples by chemiluminescence (CL). With the device Cr(III) can be detected at a concentration of 10(-7) M and a linear calibration curve was obtained from 10(-6) to 10(-4) M Cr(III). In the continuous flow injection mode the system can perform fully automated detection with a reagent consumption of only 43.2 mL per day. In addition, a general theory is presented for the performance of diffusion-based mixer/reactor devices. This is the first report of the use of a micromachined device for the quantitative detection of Cr(III) with CL. Simple instrumentation, easy operation and low reagent consumption make this system a potential candidate for the in situ monitoring of Cr(III).
引用
收藏
页码:677 / 683
页数:7
相关论文
共 40 条
[1]   Introduction of hydrogen peroxide as an oxidant in flow injection analysis: speciation of Cr(III) and Cr(VI) [J].
Andersen, JET .
ANALYTICA CHIMICA ACTA, 1998, 361 (1-2) :125-131
[2]   CHROMIUM SPECIATION AND DISTRIBUTION IN THE GREAT-LAKES [J].
BEAUBIEN, S ;
NRIAGU, J ;
BLOWES, D ;
LAWSON, G .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (04) :730-736
[3]   INVESTIGATION OF CHROMIUM(III) AND CHROMIUM(VI) SPECIATION IN WATER BY ION CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
BEERE, HG ;
JONES, P .
ANALYTICA CHIMICA ACTA, 1994, 293 (03) :237-243
[4]   Microstructure for efficient continuous flow mixing [J].
Bessoth, FG ;
deMello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1999, 36 (06) :213-215
[5]   Speciation of chromium by solid-phase extraction coupled to reversed-phase liquid chromatography with UV detection [J].
Bittner, M ;
Broekaert, JAC .
ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) :31-40
[6]  
Boucher D.F., 1959, CHEM ENG PROG, V55, P55
[7]   Fast mixing by lamination. [J].
Branebjerg, J ;
Gravesen, P ;
Krog, JP ;
Nielsen, CR .
NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, :441-446
[8]   CHROMIUM SPECIATION BY ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH BOTH INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPIC AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION [J].
BYRDY, FA ;
OLSON, LK ;
VELA, NP ;
CARUSO, JA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (02) :311-320
[9]   Liquid chromatographic separation of aqueous species of Cr(VI) and Cr(III) [J].
Collins, CH ;
Pezzin, SH ;
Rivera, JFL ;
Bonato, PS ;
Windmöller, CC ;
Archundia, C ;
Collins, KE .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :469-478
[10]   Measuring Donnan-related phenomena using a solid-state ion sensor and a concentration-step method [J].
Eijkel, JCT ;
Olthuis, W ;
Kolev, SD ;
Bergveld, P .
JOURNAL OF MEMBRANE SCIENCE, 1997, 127 (02) :203-221