Navigation improves accuracy of rotational alignment in total knee arthroplasty

被引:191
作者
Stöckl, B
Nogler, M
Rosiek, R
Fischer, M
Krismer, M
Kessler, O
机构
[1] Univ Innsbruck, Dept Orthopaed Surg, A-6020 Innsbruck, Austria
[2] CASA Grp, Stryker Europe, Thalwil, Switzerland
关键词
D O I
10.1097/01.blo.0000136835.40566.d9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Successful total knee arthroplasty is dependent on the correct alignment of implanted prostheses. Major clinical problems can be related to poor femoral component positioning, including sagittal plane and rotational malalignment. A prospective randomized study was designed to test whether an optical navigation system for total knee arthroplasty achieved greater implantation precision than a nonnavigated technique. The primary variable was rotation of the femoral component in the transverse plane, measured from postoperative radiographs and computed tomography images. Sixty-four patients were included in the study. All patients received the Duracon total knee prosthesis. The patients were randomly divided into two groups: Group C patients had conventional total knee arthroplasty without navigation; Group N patients had total knee arthroplasty using a computer-assisted knee navigation system. Analysis showed that patients in Group N had significantly better rotational alignment and flexion angle of the femoral component than patients in Group C. In addition, superior postoperative alignment of the mechanical axis, posterior tibial slope, and rotational alignment was achieved for patients in Group N. The use of a navigation system provides improved alignment accuracy, and can help to avoid femoral malrotation and errors in axial alignment.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 38 条
[1]
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, V287, P170
[2]
FEMORAL ROTATIONAL ALIGNMENT, BASED ON THE ANTEROPOSTERIOR AXIS, IN TOTAL KNEE ARTHROPLASTY IN A VALGUS KNEE - A TECHNICAL NOTE [J].
ARIMA, J ;
WHITESIDE, LA ;
MCCARTHY, DS ;
WHITE, SE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) :1331-1334
[3]
Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
[4]
Berger RA, 1998, OPERAT TECH ORTHOP, V8, P128, DOI 10.1016/S1048-6666(98)80022-0
[5]
BERGER RA, 1993, CLIN ORTHOP RELAT R, V286, P40
[6]
BERGER RA, 1993, ORTHOP T, V11, P1174
[7]
BERGER RA, 1998, CLIN ORTHOP RELAT R, V356, P144
[8]
Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses [J].
Blunn, GW ;
Joshi, AB ;
Minns, RJ ;
Lidgren, L ;
Lilley, P ;
Ryd, L ;
Engelbrecht, E ;
Walker, PS .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :281-290
[9]
DORR LD, 1986, CLIN ORTHOP RELAT R, V205, P5
[10]
EWALD FC, 1908, CLIN ORTHOP RELAT R, V248, P9