Soft x-ray circular polarizer using magnetic circular dichroism at the Fe L-3 line

被引:19
作者
Kortright, JB
Kim, SK
Warwick, T
Smith, NV
机构
[1] Materials Sciences Division, Lawrence Berkeley Natl. Laboratory, University of California, Berkeley
[2] Advanced Light Source, Lawrence Berkeley Natl. Laboratory, University of California, Berkeley
关键词
D O I
10.1063/1.119932
中图分类号
O59 [应用物理学];
学科分类号
摘要
Linearly polarized soft x-rays are converted to elliptical polarization at the Fe L-3 line (707 eV) using magnetic circular dichroism (MCD) on transmission through thin Fe films. A linear polarizer measured the transmitted polarization at different incidence angles to vary as expected from a model for in-plane magnetization, and also to exhibit a weak MCD effect at normal incidence interpreted to originate from perpendicular interface anisotropy. An MCD signal from a downstream Fe film was produced by switching the helicity of x-rays transmitted through an upstream circular polarizer. Practical considerations for optimizing the production of circular polarization are discussed, and synchrotron radiation applications using these circular polarizing filters are suggested.
引用
收藏
页码:1446 / 1448
页数:3
相关论文
共 19 条
[2]   EXPERIMENTAL CONFIRMATION OF THE X-RAY MAGNETIC CIRCULAR-DICHROISM SUM-RULES FOR IRON AND COBALT [J].
CHEN, CT ;
IDZERDA, YU ;
LIN, HJ ;
SMITH, NV ;
MEIGS, G ;
CHABAN, E ;
HO, GH ;
PELLEGRIN, E ;
SETTE, F .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :152-155
[3]   PHASE-RETARDATION AND FULL-POLARIZATION ANALYSIS OF SOFT-X-RAY SYNCHROTRON-RADIATION CLOSE TO THE CARBON-K EDGE BY USE OF A MULTILAYER TRANSMISSION FILTER [J].
DIFONZO, S ;
JARK, W ;
SCHAFERS, F ;
PETERSEN, H ;
GAUPP, A ;
UNDERWOOD, JH .
APPLIED OPTICS, 1994, 33 (13) :2624-2632
[4]   Magnetic circular x-ray dichroism in transverse geometry: Importance of noncollinear ground state moments [J].
Durr, HA ;
vanderLaan, G .
PHYSICAL REVIEW B, 1996, 54 (02) :R760-R763
[5]   CIRCULARLY POLARIZATION LINE FILTERS IN THE SOFT-X-RAY RANGE [J].
GOEDKOOP, JB ;
FUGGLE, JC ;
THOLE, BT ;
VANDERLAAN, G ;
SAWATZKY, GA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01) :429-435
[6]   DEVELOPMENT AND APPLICATION OF X-RAY PHASE RETARDERS (INVITED) [J].
HIRANO, K ;
ISHIKAWA, T ;
KIKUTA, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1604-1609
[7]  
HOCHST H, 1995, REV SCI INSTRUM, V66, P1598, DOI 10.1063/1.1145919
[8]   PRODUCTION OF CIRCULARLY POLARIZED-LIGHT FROM SYNCHROTRON RADIATION IN THE VACUUM ULTRAVIOLET REGION [J].
JOHNSON, PD ;
SMITH, NV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3) :505-508
[9]  
KIM SK, 1997, APPL PHYS LETT, V70, P66
[10]   SOFT-X-RAY FARADAY-ROTATION AT FE L(2,3) EDGES [J].
KORTRIGHT, JB ;
RICE, M ;
CARR, R .
PHYSICAL REVIEW B, 1995, 51 (15) :10240-10243