Effectiveness of composites in earthquake damage repair of reinforced concrete flared columns

被引:33
作者
Saiidi, MS [1 ]
Cheng, ZY [1 ]
机构
[1] Univ Nevada, Dept Civil Engn, Reno, NV 89557 USA
关键词
bridges; concrete columns; ductility; earthquakes; fiber reinforced plastics; rehabilitation;
D O I
10.1061/(ASCE)1090-0268(2004)8:4(306)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A method to utilize fiber composites for rapid repair of earthquake damaged flared columns was developed. Two 0.4-scale reinforced concrete columns that had been tested to failure in previous research were used. Both columns had been subjected to slow cyclic loads and had failed due to low-cycle fatigue of the longitudinal bars. To repair the columns, the damaged concrete in and around the plastic hinge was removed and the steel bars were straightened. Low-shrinkage, high-strength concrete grout was placed in the column afterward. The broken longitudinal bars were not replaced. Rather, glass and carbon fiber reinforced polymer (FRP) sheets with fibers running in the axial direction of the column were added to provide flexural strength to the columns. Additionally, glass FRP sheets with horizontal fibers were attached on the column to provide confinement and shear strength. Cyclic tests of the repaired columns indicated that the method to restore the strength was effective. Analysis using conventional constitutive relationships led to a close estimate of the lateral load response of the models.
引用
收藏
页码:306 / 314
页数:9
相关论文
共 13 条
[1]  
*AASHTO, 1998, AASHGOT LRFD BRID DE
[2]  
ACI, 1999, 31899 ACI
[3]  
[Anonymous], ACI STRUCT J
[4]  
*CALTRANS, 1999, SEISM DES CRIT
[5]  
CHENG Z, 2000, THESIS U NEVADA RENO
[6]  
FRENCH CW, 1990, ACI STRUCT J, V87, P416
[7]  
He L., 1992, SEISMIC BEHAV FLANGE
[8]  
Park R, 1975, REINFORCED CONCRETE
[9]  
PULIDO C, 2002, 021 CCER U NEV
[10]  
SAIIDI M, 2000, P 12 WORLD C EARTHQ