Reproducibility of shear rate and shear stress assessment by means of ultrasound in the common carotid artery of young human males and females

被引:56
作者
Samijo, SK
Willigers, JM
Brands, PJ
Barkhuysen, R
Reneman, RS
Kitslaar, PJEHM
Hoeks, APG
机构
[1] MAASTRICHT UNIV,CARDIOVASC RES INST,DEPT BIOPHYS,NL-6200 MD MAASTRICHT,NETHERLANDS
[2] MAASTRICHT UNIV,CARDIOVASC RES INST,DEPT PHYSIOL,MAASTRICHT,NETHERLANDS
[3] MAASTRUCHT UNIV,CARDIOVASC RES INST,DEPT SURG,MAASTRICHT,NETHERLANDS
[4] ACAD HOSP MAASTRICHT,MAASTRICHT,NETHERLANDS
关键词
blood how velocity; carotid artery; gender; reproducibility; ultrasound; wall shear rate; wall shear stress; whole blood viscosity;
D O I
10.1016/S0301-5629(97)00044-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the present study, the reliability of an ultrasonic shear rate estimating system, in terms of intrasubject intrasession, intersubject intrasession and intersubject intersession variability coefficients, for the assessment of mall shear rate (WSR) in the common carotid artery (CCA) was determined in eight presumed healthy volunteers. Measurements were performed on consecutive days (day 1, day 2 and day 7). To investigate whether there were differences in WSR due to gender, dynamic WSR in the CCA was assessed in 11 presumed healthy males (mean age 24 y) and 11 presumed healthy females (mean age 25 y). Wall shear stress (WSS) was estimated from WSR and calculated whole blood viscosity. The average intrasubject intrasession variability was about 15% for peak WSR and about 12% for mean WSR. The intersubject intrasession variability for peak WSR decreased from 19% on day 1 to 16% an day 7 and for mean WSR from 17% on day 1 to 11% on day 7. The intersubject intersession variability is on the order of 5% for peak WSR and about 4% for mean WSR. No significant differences could be detected between peak and mean WSR values on day 1, day 2 and day 7, indicating good short- and medium-term intersubject intersession reproducibilities. No differences in peak and mean WSR were found between the left and the right CCA in the male group as well as in the female group. Mean WSS was similar in males (1.3 +/- 0.3 Pa) and in females (1.2 +/- 0.2 Pa), but peak WSS was slightly, but significantly, higher in males (4.3 +/- 1.3 Pa) than in females (3.3 +/- 0.7 Pa). It can be concluded that peak and mean WSR fan be reliably determined noninvasively using ultrasound. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:583 / 590
页数:8
相关论文
共 20 条
[1]  
BINNS RL, 1989, J VASC SURG, V10, P326
[2]   A NONINVASIVE METHOD TO ESTIMATE WALL SHEAR RATE USING ULTRASOUND [J].
BRANDS, PJ ;
HOEKS, APG ;
HOFSTRA, L ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) :171-185
[3]   SECONDARY FLOW IN THE HUMAN COMMON CAROTID-ARTERY IMAGED BY MR ANGIOGRAPHY [J].
CARO, CG ;
DUMOULIN, CL ;
GRAHAM, JMR ;
PARKER, KH ;
SOUZA, SP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (01) :147-149
[4]  
CARO CG, 1977, P R SOC LOND BIOL B, V17, P105
[5]   FLOW EFFECTS ON PROSTACYCLIN PRODUCTION BY CULTURED HUMAN-ENDOTHELIAL CELLS [J].
FRANGOS, JA ;
ESKIN, SG ;
MCINTIRE, LV ;
IVES, CL .
SCIENCE, 1985, 227 (4693) :1477-1479
[6]  
FUJISHIRO K, 1982, Jikeikai Medical Journal, V29, P125
[7]  
Hocks APG, 1995, J VASC INVEST, V1, P108
[8]  
HOEKS APG, 1994, EUR J ULTRASOUND, V1, P171
[9]  
Hofstra L, 1995, J AM SOC NEPHROL, V6, P1625
[10]  
Izumo S., 1992, AM J PHYSIOL, V32, pC392