Simultaneous, quantitative determination of opiates, amphetamines, cocaine and benzoylecgonine in oral fluid by liquid chromatography quadrupole-time-of-flight mass spectrometry

被引:93
作者
Mortier, KA
Maudens, KE
Lambert, WE
Clauwaert, KM
Van Bocxlaer, JF
Deforce, DL
Van Peteghem, CH
De Leenheer, AP
机构
[1] Ghent Univ, Toxicol Lab, Fac Pharmaceut Sci, B-9000 Ghent, Belgium
[2] Ghent Univ, Lab Med Biochem & Clin Anal, B-9000 Ghent, Belgium
[3] Ghent Univ, Lab Pharmaceut Biotechnol, B-9000 Ghent, Belgium
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 779卷 / 02期
关键词
opiates; amphetamines; cocaine; benzoylecgonine;
D O I
10.1016/S1570-0232(02)00400-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method using liquid chromatography coupled to tandem mass spectrometry is described for the determination of drugs of abuse in oral fluid. The method is able to simultaneously quantify amphetamines (amphetamine, methamphetamine, MDA, MDMA and MDEA), opiates (morphine and codeine), cocaine and benzoylecgonine. Only 200 mul of oral fluid is spent for analysis. The sample preparation is easy and consists of mixed mode phase solid-phase extraction. Reversed-phase chromatography is carried out on a narrow bore phenyl type column at a flow-rate of 0.2 ml/min. A gradient is applied ranging from 6 to 67.6% methanol with ammonium formate (10 mM, pH 5.0) added to the mobile phase. The column effluent was directed into a quadrupole-time-of-flight instrument by electrospray ionization, without the use of a splitter. A validation study was carried out. Recovery ranged from 52.3 to 98.8%, within-day and between-day precision expressed by relative standard deviation were less than 11.9 and 16.8%, respectively, and inaccuracy did not exceed 11.6%. The limit of quantification was 2 ng/ml (0.66x 10(-5)-1.48 x 10(-5) M) for all compounds. Internal standards were used to generate quadratic calibration curves (r(2) > 0.999). The method was applied to real samples obtained from suspected drug users. An interference was observed from the device used to sample the oral fluid, consequently this was excluded from the method which was validated on oral fluid obtained by spitting in a test-tube. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 28 条
[1]  
Clauwaert KM, 2000, CLIN CHEM, V46, P1968
[2]   Analysis of cocaine, benzoylecgonine, and cocaethylene in urine by HPLC with diode array detection [J].
Clauwaert, KM ;
VanBocxlaer, JF ;
Lambert, WE ;
DeLeenheer, AP .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :3021-3028
[3]   CORRELATION OF SALIVA COCAINE LEVELS WITH PLASMA-LEVELS AND WITH PHARMACOLOGIC EFFECTS AFTER INTRAVENOUS COCAINE ADMINISTRATION IN HUMAN-SUBJECTS [J].
CONE, EJ ;
KUMOR, K ;
THOMPSON, LK ;
SHERER, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (04) :200-206
[4]  
CONE EJ, 1990, J ANAL TOXICOL, V14, P1
[5]  
CONE EJ, 1997, J ANAL TOXICOL, V21, P359
[6]   THERAPEUTIC DRUG-MONITORING IN SALIVA - AN UPDATE [J].
DROBITCH, RK ;
SVENSSON, CK .
CLINICAL PHARMACOKINETICS, 1992, 23 (05) :365-379
[7]  
Franke JP, 1998, J CHROMATOGR B, V713, P51
[8]  
GOLBERGER BA, 1993, CLIN CHEM, V39, P670
[9]   PRINCIPLES AND INSTRUMENTATION IN TIME-OF-FLIGHT MASS-SPECTROMETRY - PHYSICAL AND INSTRUMENTAL CONCEPTS [J].
GUILHAUS, M .
JOURNAL OF MASS SPECTROMETRY, 1995, 30 (11) :1519-1532
[10]   PHARMACOKINETICS AND PHARMACODYNAMICS OF SMOKED HEROIN [J].
JENKINS, AJ ;
KEENAN, RM ;
HENNINGFIELD, JE ;
CONE, EJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (06) :317-330