Shearing x-ray interferometer with an x-ray prism

被引:22
作者
Kohmura, Y
Ishikawa, T
Takano, H
Suzuki, Y
机构
[1] RIKEN, Harima Inst, Mikazuki, Hyogo 6795148, Japan
[2] Japan Synchrotron Radiat Res Inst, SPring 8, Mikazuki, Hyogo 6795198, Japan
关键词
D O I
10.1063/1.1536718
中图分类号
O59 [应用物理学];
学科分类号
摘要
A wave front dividing interferometer was devised in which half of a highly spatially coherent beam deflected by an x-ray prism is overlapped with another half. By placing the samples in the two beams and the x-ray imaging detector closely downstream of the sample, the differential phase of the sample is recorded on the imaging detector. The separation of the two paths at the sample plane, the amount of shear, was 2.2 mum in the present experiment. This is easily controllable by changing the distance between the sample and the imaging detector. Phase retrieval using the fringe scanning method was successfully demonstrated for various kinds of weakly absorbing samples. (C) 2003 American Institute of Physics.
引用
收藏
页码:2283 / 2285
页数:3
相关论文
共 17 条
[1]  
Allen R D, 1969, Z Wiss Mikrosk, V69, P193
[2]  
Born M., 1959, PRINCIPLES OPTICS
[3]   DIGITAL WAVEFRONT MEASURING INTERFEROMETER FOR TESTING OPTICAL SURFACES AND LENSES [J].
BRUNING, JH ;
HERRIOTT, DR ;
GALLAGHER, JE ;
ROSENFELD, DP ;
WHITE, AD ;
BRANGACCIO, DJ .
APPLIED OPTICS, 1974, 13 (11) :2693-2703
[4]   Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays [J].
Cloetens, P ;
Ludwig, W ;
Baruchel, J ;
Van Dyck, D ;
Van Landuyt, J ;
Guigay, JP ;
Schlenker, M .
APPLIED PHYSICS LETTERS, 1999, 75 (19) :2912-2914
[5]   Phase-Shifting,X-Ray shearing interferometer [J].
Iwata, K ;
Kikuta, H ;
Tadano, H ;
Hagino, H ;
Nakano, T .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (11) :6535-6539
[6]  
Kinoshita K., 1992, Proceedings of the SPIE - The International Society for Optical Engineering, V1741, P287
[7]   Production of synchrotron X-ray biprism interference patterns with control of fringe spacing [J].
Lang, AR ;
Makepeace, APW .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :59-61
[8]   Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens [J].
Miao, JW ;
Charalambous, P ;
Kirz, J ;
Sayre, D .
NATURE, 1999, 400 (6742) :342-344
[9]   Phase-contrast X-ray computed tomography for observing biological soft tissues [J].
Momose, A ;
Takeda, T ;
Itai, Y ;
Hirano, K .
NATURE MEDICINE, 1996, 2 (04) :473-475