A flow injection system based on chalcogenide glass sensors for the determination of heavy metals

被引:60
作者
Mortensen, J [1 ]
Legin, A
Ipatov, A
Rudnitskaya, A
Vlasov, Y
Hjuler, K
机构
[1] Roskilde Univ, Dept Chem & Life Sci, DK-4000 Roskilde, Denmark
[2] St Petersburg State Univ, Lab Chem Sensors, Pitersburg, Russia
[3] Dk TEKNIK Energy & Environm, Copenhagen, Denmark
关键词
flow injection; chalcogenide glass sensors; multisensor array; gas emission control;
D O I
10.1016/S0003-2670(99)00544-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection set-up for the determination of Pb(II), Cr(VI), Cu(II), Cd(II) using chalcogenide glass chemical sensors (electrodes) is presented. Seven electrodes are used to determine the four metals and also chloride ions and the signals are analysed using multivariate analysis method, including artificial neural networks. The background solution is 1 M nitric acid. It is divided in two Lines where the first one is mixed with 1.2 M sodium acetate and the other one is 1 M nitric acid. The Hg(II), Cr(VI) and Ag(I) sensors are placed in the acid line while the Pb(II), Tl(I), Cd(II) and Cu(II) electrodes are placed in the buffered line. The detection limit for Pb(II) was about 3 mu M and about 1 mu M for the other metals. In our system chloride can be determined down to about 1 mu M alone and 20 mu M simultaneously with the other species. The average error for the determination of the metals in the range from the detection limit up to about 3 mM was 10-15% for Pb(II), Cr(VI), Cu(II) and Cd(II) and about 30% for Cl-. The parameters for the flow injection system were: flow rate 0.5 ml/min and sample Volume 500 mu l. The peak widths were 100-300 s allowing a theoretical measurement rate of 15 per hour. In practice, sampling rates of about 7-10 times per hour are realistic. The system is developed as a step forward to on-line measurements of exhaust gases from waste incineration plants. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 15 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]   PROCESSING OF SIGNALS FROM AN ION-SELECTIVE ELECTRODE ARRAY BY A NEURAL NETWORK [J].
BOS, M ;
BOS, A ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1990, 233 (01) :31-39
[3]   DATA-PROCESSING BY NEURAL NETWORKS IN QUANTITATIVE CHEMICAL-ANALYSIS [J].
BOS, M ;
BOS, A ;
VANDERLINDEN, WE .
ANALYST, 1993, 118 (04) :323-328
[4]   Response characteristics and application of chalcogenide glass Cr(VI) selective electrode [J].
Christensen, JH ;
Clemmesen, P ;
Hansen, GH ;
Liltorp, K ;
Mortensen, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (03) :239-243
[5]  
ESBENSEN K, 1994, MULTIVARIATE ANAL PR
[6]   Tasting of beverages using an electronic tongue [J].
Legin, A ;
Rudnitskaya, A ;
Vlasov, Y ;
Di Natale, C ;
Davide, F ;
D'Amico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) :291-296
[7]   Chemical sensor array for multicomponent analysis of biological liquids [J].
Legin, A ;
Smirnova, A ;
Rudnitskaya, A ;
Lvova, L ;
Suglobova, E ;
Vlasov, Y .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :131-135
[8]   ANALYTICAL APPLICATIONS OF CHALCOGENIDE GLASS CHEMICAL SENSORS IN ENVIRONMENTAL MONITORING AND PROCESS-CONTROL [J].
LEGIN, AV ;
BYCHKOV, EA ;
VLASOV, YG .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :309-311
[9]   Non-selective chemical sensors in analytical chemistry: from "electronic nose" to "electronic tongue" [J].
Vlasov, Y ;
Legin, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :255-260
[10]   SILVER BROMIDE BASED CHALCOGENIDE GLASSY CRYSTALLINE ION-SELECTIVE ELECTRODES [J].
VLASOV, YG ;
MOSKVIN, LN ;
BYCHKOV, EA ;
GOLIKOV, DV .
ANALYST, 1989, 114 (02) :185-190