The sensitivity of fixed-bed biological perchlorate removal to changes in operating conditions and water quality characteristics

被引:29
作者
Brown, JC [1 ]
Snoeyink, VL [1 ]
Raskin, L [1 ]
Lin, R [1 ]
机构
[1] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
关键词
perchlorate; biologically active carbon; biological filtration; drinking water treatment;
D O I
10.1016/S0043-1354(02)00243-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Flow rate, electron donor addition, and biomass control were evaluated in order to optimize perchlorate (ClO4-) removal from drinking water using biologically active carbon (BAC) filtration. Influent dissolved oxygen (DO) was lowered from ambient conditions to approximately 2.5 mg/L for all experiments using a nitrogen sparge. When influent nitrate concentration was 0-2.0 mg/L, 1.6-2.8 mg/L as carbon of acetate or ethanol was required to achieve and sustain the complete removal of 50 mug/L perchlorate in a BAC filter. Most or all of the exogenous acetate and ethanol was removed during biofiltration. When a 72-h electron donor feed failure was simulated, a maximum perchlorate breakthrough of 18 mug/L was observed and, once electron donor was reapplied, 9 days were required to reestablish complete perchlorate removal. During a 24-h electron donor feed failure simulation, the maximum effluent perchlorate concentration detected was 6.7 mug/L. Within 24h of reactivating the electron donor, the filter regained its capacity to consistently remove 50 mug/L perchlorate to below detection. Although biomass growth diminished the filter's ability to consistently remove perchlorate, a cleaning procedure immediately restored stable, complete perchlorate removal. This cleaning procedure was required approximately every 50 days (4800 bed volumes) when influent DO concentration was 2.5 mg/L. Empty-bed contact time (EBCT) experiments showed that 80% perchlorate removal was achieved using a 5-min EBCT, and complete perchlorate removal was observed for an EBCT of 9 min. It was also demonstrated that BAC filtration consistently removed perchlorate to below detection for influent perchlorate concentrations ranging from 10 to 300 mug/L, influent sulfate concentrations between 0 and 220 mg/L, influent pH values of 6.5-9.0, and operating temperatures of 5-22degreesC. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:206 / 214
页数:9
相关论文
共 18 条
[1]
*AWWA, 1997, WAT PERCHL DET 0901
[2]
Rotating ion-exchange system removes perchlorate [J].
Betts, KS .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (19) :454A-455A
[3]
Brown JC, 2002, J AM WATER WORKS ASS, V94, P70
[4]
*CDHS DIV DRINK WA, 1997, P AM WAT WORKS ASS R
[5]
Evaluation of censored data methods to allow statistical comparisons among very small samples with below detection limit observations [J].
Clarke, JU .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (01) :177-183
[6]
Removal of perchlorate in ground water with a flow-through bioreactor [J].
Giblin, T ;
Herman, D ;
Deshusses, MA ;
Frankenberger, WT .
JOURNAL OF ENVIRONMENTAL QUALITY, 2000, 29 (02) :578-583
[7]
Gullick RQ, 2001, J AM WATER WORKS ASS, V93, P66
[8]
Fixed-bed bioreactor treating perchlorate-contaminated waters [J].
Kim, K ;
Logan, BE .
ENVIRONMENTAL ENGINEERING SCIENCE, 2000, 17 (05) :257-265
[9]
Logan B.E., 1998, Bioremed. J, P69, DOI DOI 10.1080/10889869891214222
[10]
Mallevialle Joel, 1987, Identification and Treatment of Taste and Odors in Drinking Water"