Post-prostatectomy incontinence and the artificial urinary sphincter: A long-term study of patient satisfaction and criteria for success

被引:163
作者
Litwiller, SE
Kim, KB
Fone, PD
White, RWD
Stone, AR
机构
[1] Department of Urology, University of California, Davis Medical Center, Sacramento, CA
关键词
artificial organs; urinary incontinence; prostatectomy;
D O I
10.1016/S0022-5347(01)65408-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We investigated patient satisfaction with the artificial urinary sphincter and established criteria for a successful outcome by inquiring about patient perceived satisfaction, continence achieved and comparison with the surgeon office records. Materials and Methods: During 9 years 65 patients with post-prostatectomy incontinence underwent placement of the AMS800* artificial urinary sphincter. Review of charts and a telephone questionnaire were conducted to determine patient perceived satisfaction. Results: A total of 50 patients participated in the survey. Median followup was 23.4 months. Preoperative incontinence was severe. Of the patients 90% reported continuous leakage, and 70% wore an average of 6 diapers and 24% wore an average of 7.4 pads daily. The long-term complete continence rate was 20%. Of the patients with wetness 55% had leakage of a few drops daily and 22% had leakage of less than a teaspoon. Of all patients 50% had leakage daily, 24% had leakage 1 or more times a week and wore an average of 1.5 pads per day, and 6% reported changing clothes due to wetness. A total of 90% of the patients reported satisfaction with the artificial urinary sphincter and 96% stated that they would recommend or had recommended the artificial urinary sphincter to a friend. In retrospect, 92% of the patients would have the artificial urinary sphincter placed again, 90% of those undergoing revision reported no change in satisfaction and 14% reported improved sexual activity. Conclusions: Patient satisfaction with the artificial urinary sphincter for post-prostatectomy incontinence is uniformly high. Although postoperative continence was not 100%, relative improvement in continence was the most significant factor affecting patient perceived outcome. Using these parameters criteria for a successful outcome can be established, and patient concerns regarding the artificial urinary sphincter can be dispelled.
引用
收藏
页码:1975 / 1980
页数:6
相关论文
共 21 条
[1]   INCONTINENCE AFTER RADICAL PROSTATECTOMY - DETRUSOR OR SPHINCTER CAUSES [J].
CHAO, R ;
MAYO, ME .
JOURNAL OF UROLOGY, 1995, 154 (01) :16-18
[2]   PROXIMAL ARTIFICIAL SPHINCTER CUFF REPOSITIONING FOR URETHRAL ATROPHY INCONTINENCE [J].
COUILLARD, DR ;
VAPNEK, JM ;
STONE, AR .
UROLOGY, 1995, 45 (04) :653-656
[3]   EXPERIENCE WITH THE ARTIFICIAL URINARY SPHINCTER MODEL-AS800 IN 148 PATIENTS [J].
FISHMAN, IJ ;
SHABSIGH, R ;
SCOTT, FB .
JOURNAL OF UROLOGY, 1989, 141 (02) :307-310
[4]   PATIENT-REPORTED COMPLICATIONS AND FOLLOW-UP TREATMENT AFTER RADICAL PROSTATECTOMY - THE NATIONAL MEDICARE EXPERIENCE - 1988-1990 (UPDATED JUNE 1993) [J].
FOWLER, FJ ;
BARRY, MJ ;
LUYAO, G ;
ROMAN, A ;
WASSON, J ;
WENNBERG, JE .
UROLOGY, 1993, 42 (06) :622-629
[5]   THE MODEL AS-800 ARTIFICIAL URINARY SPHINCTER - MAYO-CLINIC EXPERIENCE [J].
GOLDWASSER, B ;
FURLOW, WL ;
BARRETT, DM .
JOURNAL OF UROLOGY, 1987, 137 (04) :668-671
[6]   URODYNAMICS AND THE ETIOLOGY OF POSTPROSTATECTOMY URINARY-INCONTINENCE - THE INITIAL COLUMBIA EXPERIENCE [J].
GOLUBOFF, ET ;
CHANG, DT ;
OLSSON, CA ;
KAPLAN, SA .
JOURNAL OF UROLOGY, 1995, 153 (03) :1034-1037
[7]   MAYO-CLINIC EXPERIENCE WITH USE OF THE AMS800 ARTIFICIAL URINARY SPHINCTER FOR URINARY-INCONTINENCE FOLLOWING RADICAL PROSTATECTOMY [J].
GUNDIAN, JC ;
BARRETT, DM ;
PARULKAR, BG .
JOURNAL OF UROLOGY, 1989, 142 (06) :1459-1461
[8]   MAYO-CLINIC EXPERIENCE WITH THE AS800 ARTIFICIAL URINARY SPHINCTER FOR URINARY-INCONTINENCE AFTER TRANSURETHRAL RESECTION OF PROSTATE OR OPEN PROSTATECTOMY [J].
GUNDIAN, JC ;
BARRETT, DM ;
PARULKAR, BG .
UROLOGY, 1993, 41 (04) :318-321
[9]   POSTPROSTATECTOMY INCONTINENCE .1. THE URODYNAMIC FINDINGS IN 107 MEN [J].
LEACH, GE ;
YUN, SK .
NEUROUROLOGY AND URODYNAMICS, 1992, 11 (02) :91-97
[10]   SUCCESS OF THE NARROW-BACKED CUFF DESIGN OF THE AMS800 ARTIFICIAL URINARY SPHINCTER - ANALYSIS OF 144 PATIENTS [J].
LEO, ME ;
BARRETT, DM .
JOURNAL OF UROLOGY, 1993, 150 (05) :1412-1414